28
9 Specification
Table 9.1 Technical Data
Model
KSG-1K-SM
KSG-1.5K-SM
KSG-2K-SM
KSG-3K-SM
DC-Input Parameters
Max. Input Power (W)
1150 1600 2100 3100
Max. Input Voltage (Vdc)
500
MPPT Operating Range (Vdc)
100-490
Max.input current per MPPT
tracker (A)
11 11 11 13
Rated Input Voltage (Vdc)
380
Numbers of Input
1
MPPT Channel
1
AC-Output Parameters
Max. Output Power (W)
1000
1500 2000
3000
Rated Output Power (W)
1000
1500 2000
3000
Output Voltage Range (Vac)
Refer to
Table 9-2
Max. Output Current
(A)
4.5 7 9 14
Rated Output Voltage (Vac)
220/230
Rated Output Current (A)
4.5 7
9 14
Output Frequency Range (Hz)
Refer to Table 9-2
Power Factor
>0.99
Current Harmonic Distortion
(THDi)
<3%
Max. Efficiency
97.0% 97.5% 97.5% 97.6%
European Efficiency
96.5% 97.0% 97.0% 97.0%
Environment
Protective Level
IP65
Working Temperature Range
( )
-25~+60
Humidity
0~95%, no condensation
Altitude (m)
≤2000
Ventilation
natural cooling
Consumption During Night
Time (W)
<0.2