OPERATING THE GENERATOR
OPERATING PROCEDURE TO STOP
SUPPLYING THE ELECTRIC POWER
1. Turn OFF all electrical device switches for
connected loads.
2. Turn OFF the circuit breaker.
(1) Circuit breaker (A) “STOP”
3. Allow the engine to run with no load for
about 5 minutes before stopping the
engine completely.
4. Turn the main switch (key) to the “OFF”
position.
(1) Main switch (Key) (A)”OFF”
5.Turn the fuel tank tap to the “OFF”
position.
(1) Fuel tank tap (A) “OFF”