1. GENERAL INFORMATION
1-36
XCITING 500/250
POOR PERFORMANCE (AT HIGH SPEED)
cFaulty ignition unit
dFaulty A.C. generator
cImproperly adjusted valve
clearance
dWorn valve seat
cEmpty fuel tank
dClogged fuel tube or filter
eFaulty fuel pump
fCracked
fuel pump vacuum
tube
cClean and unclog
cCam timing gear aligning
marks not aligned
cFaulty spring
Inspection/Adjustment Symptom Probable Cause
Check ignition timing
Check carburetor jets
for clogging
Check fuel pump fo
r
fuel supply
Correct timing
Incorrect timing
Check valve spring
tension
Check valve clearance
Fuel flows freely
Fuel flow restricted
Correc
t
Incorrec
t
Not clogged
Clogged
Correctly adjusted
Incorrectly adjusted
Not weakened
Weak spring
Check valve timing