3.6.30 EAN-128
Type / properties:
Linear code
Activation sequence:
<Esc>(s24720T<Base Data><Stop Character>
For an explanation on selecting the stop character and the optional parameters, see
chapters 3.2.1. and 3.2.6.
Default - parameters:
v parameter 29
p parameter 1
b parameter 6,12,18,24
Additional properties:
Size of base data: 1 to 44, maximum size is limited to 35 symbols
Character set: All printable characters from 00 to 126
Example:
<Esc>(s24720T1234567890<CR>
94