EasyManuals Logo
Home>Launch>Test Equipment>X431 Scopebox

Launch X431 Scopebox User Manual

Launch X431 Scopebox
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
LAUNCH X431 PAD Scopebox User’s Manual
in most applications. Edge trigger only detects the edges, polarities, and
voltage of signal. When the voltage of measured signal varies as identical as
the preset one (rising edge or falling edge), and the value becomes same as
trigger voltage, the oscilloscope will be triggered and capture the waveform.
[Pulse Width]: T
rigger happens when it reaches to the pulse width.
Fig. 3-5 and Fig. 3-6 show edge trigger, pulse widt
h trigger setting interfaces.
Fig. 3-5
Fig. 3-6
<2> Trigger Sweep
Auto, Normal and Single are included.
Auto: It indicates that no matter w
hether it meets the trigger conditions, it will
refresh the waveform in real time. In this case, the waveform displayed on the
screen seems swaying;
Normal: Only
it meet
s the trigger conditions can trigger be activated.
Otherwise the waveform will keep still.
Single: In this mode, it only
captures the waveform that generates for the first
time the trigger conditions are met, and then stops after finishing capture.
10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Launch X431 Scopebox and is the answer not in the manual?

Launch X431 Scopebox Specifications

General IconGeneral
BrandLaunch
ModelX431 Scopebox
CategoryTest Equipment
LanguageEnglish

Related product manuals