Lighting Information and Operation
WARNING
If you do not follow these instructions exactly, a fire
or explosion may result causing property damage,
personal injury or loss of life.
BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire de
partment.
Use only your hand to turn the gas control knob(s). Never
use tools. If the knob will not turn by hand, do not try to repair
it, call a qualified service technician. Force or attempted re-
pair may result in a fire or explosion.
PLACING UNIT INTO OPERATION
(Millivolt Valves with Piezo Ignitor)
Fireplaces which include a millivolt valve are equipped
with a pilot which must be lit by a Piezo ignitor (red ignitor
button). When lighting the pilot, follow these instructions
exactly.
GAS VALVE OPERATION – Millivolt Valve (Figure 2)
1 – STOP! Read the safety information at the beginning
of this section.
2 – Turn OFF the burner switch (if applicable), or set the
thermostat to the lowest setting (if applicable).
3 – Turn off all electrical power to appliance (if applicable).
4 – Open the control access panel. See figure1.
5 – Push in gas control knob slightly and turn clockwise
to OFF.
NOTE – Knob cannot be turned from PILOT to OFF un-
less knob is pushed in slightly. Do not force.
Insert the tip of a finger of each hand (with the back of the
hands toward the panel) into the cutout in the bottom of
the panel at the positions shown, and rotate the panel
down.
The control access panel becomes hot during
unit operation, and must be opened with care:
TO OPEN THE CONTROL ACCESS PANEL
FIGURE 1
6 – Wait five (5) minutes to clear out any gas. Then, smell
for gas, including near the floor. If you smell gas, STOP!
Follow the safety instructions given in the column to the
left. If you do not smell gas, go to the next step.
7 – Press partially and turn gas valve knob counterclock-
wise to PILOT.
8 – Push control knob in until it stops and hold knob in this
position. IMMEDIATELY light the pilot by pushing the
red Piezo ignitor button. Continue to press control knob
for 25 seconds after the pilot is lit. Release knob. It
should pop back up. Pilot should remain lit. If pilot goes
out, repeat steps 5 through 8.
GAS VALVE SHOWN IN PILOT POSITION
CONTROL
KNOB
HI/LO FLAME
ADJUSTMENT KNOB
MILLIVOLT GAS VALVE
FIGURE 2
9 – Press partially and turn gas valve knob counterclock-
wise to ON.
10 –Restore electrical power to appliance (if applicable)
11 –Turn ON the burner switch (if applicable), or set the
thermostat to the desired setting (if applicable).
12 –Close the control access panel.
NOTE – If gas valve is turned to OFF from ON or PILOT
while appliance is in operation, gas valve will latch in OFF
position for 25 seconds.