Heat Mode Selection -
Configuring / Detecting
Electric Heat Sections
IMPORTANT: All electric heat installations
require the Air Handler Control (AHC) to be
manually configured to detect number of heat
sections.
Which Heat
Mode?
Set desired Heating Mode Blower Speed jumper pin.
Electric heat is stages by room thermostat. (AHC
comes with factory jumper between W1/W2 and
W2/W3)
Refer to Air Handler Control Checkout flow diagram for
operation.
Configuration
Standard
EVENHEAT
AHC in Idle Mode
(No heating cooling or
indoor fan operation)
To enter electric heat configuration,
push and hold button next to single
character display until dash symbol
(solid bar) appears, then release
button.
Turn room thermostat to
OFF.
Ye s
Solid dash
starts
blinking on
single
character
display.
Push and hold button until the solid H symbol is displayed on the single character
display, then release button.
Finished
No
NOTE - All field replacement AHC will require
configuring/detecting electric heat sections.
Set desired Heating Mode Blower Speed jumper pin.
Install and wire discharge air temperature sensor.
Set desired Target Discharge Temperature jumper
pin. If jumper pin is missing or discharge air
temperature sensor is not detected, AHC defaults to
Standard Heat mode. Target settings are 85, 100, 115
and 130ºF)
Refer to EVENHEAT Operation flow diagram for
operation.
1AHC will start the indoor blower motor to the selected heat jumper speed setting and cycle the electric heat relays ON to automatically detect number of electric
heat sections. (Electric heat section may be wired to energize more than one element)
2AHC waits for maximum of ten seconds to detect electric heat 22 volt DC relay coils are energizing:
AIf relay coil current is detected within ten seconds,
AHC will show a “1” on the single character display indicating that the first stage has been detected. As
each additional heat section is detected, single character display on the AHC will display that electric element number. (Example: Last number displayed by
the single character display is 3, the AHC is configured to operate three electric heat sections.)
B If relay coil current is not detected within ten seconds,
the AHC will exit the test mode and resume operation with electric heat disabled.
3AHC will automatically exit configuration when completed. To verify that the number of electric sections detected matches the installed electric heat package, the
field MUST CONFIRM that the last number the single character displayed before exiting the Configuring/Detection mode matches the number of installed electric
heat sections. AHC stores the number of electric heat stages in non-volatile memory.
4Verify that the indoor blower motor will continue to operate for an additional 30 seconds.
NOTE - If AHC push button is pushed or power is cycled on AHC is unable to verify all 22 volt DC electric heat relay(s) were energized using electric heater detection,
configuration will be stopped. Configuration function must be repeated.
AIR HANDLER CONTROL (AHC)
SINGLE CHARACTER
DISPLAY
PUSH BUTTON
FIGURE 12. Heat Mode Selection

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox ECB38 Series and is the answer not in the manual?

Lennox ECB38 Series Specifications

General IconGeneral
BrandLennox
ModelECB38 Series
CategoryHeat Pump
LanguageEnglish

Related product manuals