EasyManuals Logo
Home>Lennox>Chiller>ECOLEAN EAR 0812SM

Lennox ECOLEAN EAR 0812SM User Manual

Lennox ECOLEAN EAR 0812SM
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
1 F 2 F 3 F 4 F 5 F 6 F
LP1 4,5 6 4,5 6 3,5 4,5 2,5 3,5 3,5 4,5 3,5 4,5
LP2 4,5 6 4,5 6 3,5 4,5 2,5 3,5 3,5 4,5 3,5 4,5
HP1 43 34 43 34 43 34 43 34 43 34 43 34
HP2 43 34 43 34 43 34 43 34 43 34 43 34
HPR11 22 28 22 28 22 28 22 28
FSC (6A) FSC1 (12A/20A)
HPR12 37 30 37 30 37 30 37 30
HPR21 22 28 22 28 22 28 22 28
FSC2 (6A) FSC2 (12A/20A)
HPR22 37 30 37 30 37 30 37 30
PT1/PT2 N/A N/A N/A N/A (*) (*)
B2 (*) (*) (*) (*) (*) (*)
7 F = 2F + 5F 8 F = 3F + 5F 9 F = 4F + 5F
LP1 3,5 4,5 3,5 4,5 2,5 3,5
LP2 3,5 4,5 3,5 4,5 2,5 3,5
HP1 43 34 43 34 43 34
HP2 43 34 43 34 43 34
HPR11
FSC1 (6A) FSC1 (6A) FSC1 (6A)
HPR12
HPR21
FSC2 (6A) FSC2 (6A) FSC2 (6A)
HPR22
PT1/PT2 (*) (*) (*)
B2 (*) (*) (*)
10F = 2F + 6F 11 F = 3F + 6F 12 F = 4F + 6F
LP1 3,5 4,5 3,5 4,5 2,5 3,5
LP2
3,5 4,5 3,5 4,5 3,5 4,5
HP1 43 34 43 34 43 34
HP2 43 34 43 34 43 34
HPR11
FSC1 (12A/20A) FSC1 (12A/20A) FSC1 (12A/20A)
HPR12
HPR21
FSC2 (12A/20A) FSC2 (12A/20A) FSC2 (12A/20A)
HPR22
PT1/PT2 (*) (*) (*)
B2 (*) (*) (*)
14
COOLING ONLY
1003SM TO 1804SM UNITS
1.7.- SAFETY DEVICES
COOLING
EAC
UNIT
STD/FP1/FP2
KIT LOW WATER Tª
0ºC (STD/FP1/FP2)
KIT LOW WATER Tª
-5ºC (STD/FP1/FP2)
KIT LOW WATER Tª
-10ºC (STD/FP1/FP2)
COOLING LOW
AMBIENT KIT -15ºC
(STD)
COOLING LOW
AMBIENT KIT -15ºC
(FP1/FP2)
cycle set reset cycle set reset cycle set reset cycle set reset cycle set reset cycle set reset
cooling cooling cooling cooling cooling cooling
cooling cooling cooling cooling cooling cooling
cooling
cooling cooling cooling cooling cooling
cooling cooling cooling cooling cooling cooling
cooling cooling cooling cooling
cooling cooling cooling cooling
cooling cooling cooling cooling
cooling
cooling cooling cooling
COOLING
EAC
KIT LOW WATER Tª
0ºC COOLING -15ºC
(STD)
KIT LOW WATER Tª
-5ºC COOLING -15ºC
(STD)
KIT LOW WATER Tª
-10ºC COOLING -15ºC
(STD)
cycle set reset cycle set reset cycle set reset
cooling cooling cooling
cooling cooling cooling
cooling cooling cooling
cooling cooling cooling
COOLING
EAC
KIT LOW WATER Tª
0ºC COOLING -15ºC
(FP1/FP2)
KIT LOW WATER Tª
-5ºC COOLING -15ºC
(FP1/FP2)
KIT LOW WATER Tª
-10ºC COOLING -15ºC
(FP1/FP2)
cycle set reset cycle set reset cycle set reset
cooling cooling cooling
cooling cooling cooling
cooling cooling cooling
cooling cooling cooling
LP / HP / PT / HPR values in Bar. B values in ºC.
(*) CLIMATIC 40 REGULATION
1.-FAN SPEED REGULATION (PT1 y PT2)
EAR STD/FP1/FP2
-Fan start-up 28 Bar
-Cut off 22 Bar
2.-DEFROST CYCLE (PT1 y PT2)
-Start 5,7 Bar
-End 35 Bar
3.-ALARMAS
ANTIFREEZE ALARM (B2)
CUT RESET
STD Unit +3ºC +8ºC
Low water Tª option 0ºC -3ºC -2ºC
Low water Tª option -10ºC -8ºC -7ºC
Low water Tª option -15ºC -13ºC -12ºC
(*) FAN SPEED REGUTATION WITH PROPORTIONAL
CONDENSING PRESSURE CONTROL (FSC/FSC1/FSC2)
(PT1/PT2)
Speed
1.- GENERAL CHARACTERISTICS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox ECOLEAN EAR 0812SM and is the answer not in the manual?

Lennox ECOLEAN EAR 0812SM Specifications

General IconGeneral
BrandLennox
ModelECOLEAN EAR 0812SM
CategoryChiller
LanguageEnglish

Related product manuals