1 F 2 F 3 F 4 F 5 F 6 F = 2F + 3F 7 F = 2F + 4F 8 F = 2F + 5F
LP1 4,5 6 4,5 6 4,5 6 3,5 4,5 2,5 3,5 4,5 6 3,5 4,5 2,5 3,5
HP1 43 34 43 34 43 34 43 34 43 34 43 34 43 34 43 34
PT1 N/A N/A N/A N/A N/A N/A N/A N/A
HPR N/A 22 28 N/A N/A N/A 22 28 22 28 22 28
B2 (*) (*) (*) (*) (*) (*) (*) (*)
B3 (*) (*) (*) (*) (*) (*) (*) (*)
9 F 10 F 11 F 12 F
LP1 3,5 4,5 3,5 4,5 3,5 4,5 2,5 3,5
HP1 43 34 43 34 43 34 43 34
PT1 (*) (*) (*) (*)
HPR N/A N/A N/A N/A
B2 (*) (*) (*) (*)
B3 N/A N/A N/A N/A
1 B 2 B 3 B 4 B 5 B 6 B = 2B + 5B 7 B = 3B + 5B 8 B = 4B + 5B
LP1 4,5 6 4,5 6 3,5 4,5 2,5 3,5 4,5 6 4,5 6 3,5 4,5 2,5 3,5
PT1 1,7 2,7 1,7 2,7 1,7 2,7 1,7 2,7 1,7 2,7 1,7 2,7 1,7 2,7 1,7 2,7
HP1 43 34 43 34 43 34 43 34 43 34 43 34 43 34 43 34
PT1 (*) (*) (*) (*) (*) (*) (*) (*)
DT N/A N/A N/A N/A
B2 (*) (*) (*) (*) (*) (*) (*) (*)
X1 X2 X3 X4 X5 X6
18 18,1 28 35 39,1 40
18 19 20 24 25 26
18 19 20 24 25 26
13
1.7.- SAFETY DEVICES
COOLING ONLY
0251SM TO 0812SM UNITS
HEAT PUMP
COOLING
EAC
UNIT
STD/FP1
UNIT
FP2
KIT LOW WATER Tª
0ºC (STD/FP1)
KIT LOW WATER Tª
-5ºC (STD/FP1)
KIT LOW WATER Tª
-10ºC (STD/FP1)
KIT LOW WATER Tª
0ºC (FP2)
KIT LOW WATER Tª
-5ºC (FP2)
KIT LOW WATER Tª
-10ºC (FP2)
cycle set reset cycle set reset cycle set reset cycle set reset cycle set reset cycle set reset cycle set reset cycle set reset
cooling cooling cooling cooling cooling cooling cooling cooling
cooling cooling cooling cooling cooling cooling cooling cooling
cooling cooling cooling cooling
COOLING
EAC
COOLING LOW
AMBIENT KIT -15ºC
(STD/FP1/FP2)
KIT LOW WATER Tª
0ºC COOLING -15ºC
(STD/FP1/FP2)
KIT LOW WATER Tª
-5ºC COOLING -15ºC
(STD/FP1/FP2)
KIT LOW WATER Tª
-10ºC COOLING -15ºC
(STD/FP1/FP2)
cycle set reset cycle set reset cycle set reset cycle set reset
cooling cooling cooling cooling
cooling cooling cooling cooling
HEATING
EAR
UNIT
STD/FP1/FP2
KIT LOW WATER Tª
0ºC (STD/FP1/FP2)
KIT LOW WATER Tª
-5ºC (STD/FP1/FP2)
KIT LOW WATER Tª
-10ºC (STD/FP1/FP2)
HEATING LOW
AMBIENT KIT -15ºC
(STD/FP1/FP2)
KIT LOW WATER Tª
0ºC HEATING -15ºC
(STD/FP1/FP2)
KIT LOW WATER Tª
-5ºC HEATING -15ºC
(STD/FP1/FP2)
KIT LOW WATER Tª
-10ºC HEATING -15ºC
(STD/FP1/FP2)
cycle set reset cycle set reset cycle set reset cycle set reset cycle set reset cycle set reset cycle set reset cycle set reset
cooling cooling cooling cooling cooling cooling cooling cooling
heating heating heating heating heating heating heating heating
c/h c/h c/h c/h c/h c/h c/h c/h
heating
118ºC
differential 7
heating
118ºC
differential 7
heating
118ºC
differential 7
heating
118ºC
differential 7
LP / HP / PT / HPR values in Bar. B values in ºC.
1.-FAN SPEED REGULATION (B3ó PT1)
EAC
(1 and 2)
EAR
(Cooling)
STD/FP1
Speed
MOD. Unit
EAC (1) ºC
EAC (2) Bar
EAR (Cooling) Bar
EAC
(2)
EAR
(Cooling)
FP2
Fan start-up 28 Bar
Cut-off 22 Bar
(1) Without PT1
(2) With PT1
(*) CLIMATIC 40 REGULATION
2.-DEFROST CYCLE (PT1)
Start 5,7 Bar
End 35 Bar
3.-ALARMS
ANTIFREEZE ALARM (B2)
CUT RESET
STD Unit +3ºC +8ºC
Low water Tª option 0ºC -3ºC -4ºC
Low water Tª option -10ºC -8ºC -7ºC
Low water Tª option -15ºC -13ºC -12ºC
1.- GENERAL CHARACTERISTICS