Page #36 background imageLoading...
Page #36 background image
35
9.Troubleshooting
9.1 Display board
Thi s indicator illuminates whe n the air conditioner is in AUTO operation.
AUTO indicator
DE FROST indicator (For Cooling & Heating mo dels only)
Thi s indicator illuminates whe n the air conditioner starts defrosting automati cally or
when the warm air control fea ture is activated in heating oper ation.
1
22
3
4
5
1
22
3
4
Displays the te mperature settings when the air conditioner is operational.
This indicator fl ashe s after power is on and illuminates when the unit is in operation.
This indicator il luminates when TIMER is set ON/OFF.
OPERATION in dicator
TIMER indicat or
TEMPERATUR E indicator
5
Signal receptor
9.2 For all heat pump model
r Extinguish
Flash at 5Hz
Failure phenomenon Operation lamp Timer lamp
Indoor fan speed has been out of control for over 1 minute
X
Indoor room temp. or evaporator sensor is open circuit or short circuit
On
Over current protection of the compressor occurs 4 times X
EEROM error On
No over-zero signal

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox GCM07N and is the answer not in the manual?