3
INTRODUCTION
Introduction
This appliance is a gas- red direct vent hot water boiler
with cast aluminum boiler sections.
The heating system water absorbs large amounts of
heat from the cast aluminum heat exchanger, cooling
ue gases and causing condensation.
Sealed combustion, premix gas burner, and low ame
temperature means reduced CO and NOx emissions,
which contribute to cleaner and healthier environment.
This appliance takes its combustion air directly from
outdoors (sealed combustion) and does not compete
with building occupants for fresh air.
Sealed combustion (also known as “direct vent”)
is safest and best way to obtain plenty of clean
combustion air.
Dimensions .................................................................................................................... 2
Introduction ................................................................................................................... 3
Important Safety Information ........................................................................................... 4
Boiler Ratings & Capacities ..............................................................................................5
Boilers For Use At High Altitude - United States Installations ................................................ 6
Before Installing The Boiler ..............................................................................................8
Boiler Installation ...........................................................................................................9
Near Boiler Piping ......................................................................................................... 11
Combustion Air And Vent Pipe ........................................................................................ 22
Gas Supply Piping ......................................................................................................... 28
Electrical Wiring ........................................................................................................... 30
Controls And Accessories ............................................................................................... 34
Start Up ...................................................................................................................... 36
Operating Instructions ................................................................................................... 37
Detailed Sequence Of Operation ..................................................................................... 38
Veri cation Procedure And Adjustment ............................................................................ 42
Differential Air Pressure Switch Check - All Models ............................................................ 45
Negative Pressure Switch Check ..................................................................................... 46
Maintenance And Cleaning ............................................................................................. 47
Troubleshooting ............................................................................................................ 49
Troubleshooting - High Limit Control And LWCO ............................................................... 50
Troubleshooting -Hydrostat High Limit Control And LWCO .................................................. 51
Appendix A - Water Quality, Water Treatment And Freeze Protection ........................58
Installation And Check-Out Certi cate ............................................................................. 62
Induced draft fan draws in outside combustion
air, takes cooler ue gases from boiler unit and
provides positive removal of ue gases from the
building through readily available PVC, CPVC and PP
(Polypropylene) pipes.
These low pressure gas- red hot water boilers are
design certi ed by CSA International for use with
natural gas and propane gas.
Boilers are constructed and hydrostatically tested for
maximum working pressure of 50 psig (pounds per
square inch gage) in accordance with A.S.M.E. Boiler
and Pressure Vessel Code Section IV Standards for
heating boilers.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox GWB9-050IH-3 and is the answer not in the manual?

Lennox GWB9-050IH-3 Specifications

General IconGeneral
BrandLennox
ModelGWB9-050IH-3
CategoryBoiler
LanguageEnglish

Related product manuals