Page 12
FIGURE 13
VAPOR LINE SERVICE VALVE (VALVE OPEN)
SCHRADER
VALVE
SERVICE PORT
SERVICE PORT
CAP
INSERT HEX
WRENCH HERE
INLET (TO
INDOOR COIL)
OUTLET (TO
COMPRESSOR)
STEM CAP
SCHRADER VALVE OPEN
TO LINE SET WHEN VALVE IS
CLOSED (FRONT SEATED)
SERVICE
PORT
SERVICE PORT
CAP
RETAINING RING
STEM CAP
INSERT HEX
WRENCH HERE
VAPOR LINE SERVICE VALVE (VALVE CLOSED)
(VALVE FRONT
SEATED)
INLET (TO
INDOOR COIL)
OUTLET (TO
COMPRESSOR)
Vapor Line (Ball Type) Service Valve(5 Ton Only)
A ball-type full service valve is used on HP29 5 ton units.
These vapor line service valves function the same way,
differences are in construction. Valves are not rebuildable.
If a valve has failed it must be replaced. A ball valve is
illustrated in figure 14.
The ball valve is equipped with a service port. A schrader
valve is factory installed. A service port cap is supplied to
protect the schrader valve from contamination and assure a
leak free seal.
VAPOR LINE (BALL TYPE) SERVICE VALVE
(VALVE OPEN)
FIGURE 14
SCHRADER VALVE
SERVICE PORT
SERVICE
PORT
CAP
STEM CAP
INLET
(FROM INDOOR COIL)
OUTLET
(TO
COMPRESSOR)
STEM
USE ADJUSTABLE WRENCH
ROTATE STEM CLOCKWISE 90_ TO CLOSE
ROTATE STEM COUNTER-CLOCKWISE 90_ TO OPEN
BALL
(SHOWN OPEN)

Other manuals for Lennox HP29 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox HP29 Series and is the answer not in the manual?

Lennox HP29 Series Specifications

General IconGeneral
BrandLennox
ModelHP29 Series
CategoryHeat Pump
LanguageEnglish

Related product manuals