OPTIONS / ACCESSORIES
Item Description
Model
Number
Catalog
Number
Unit Model No
092 102 120 150
COOLING SYSTEM
Condensate Drain Trap PVC - C1TRAP20AD2 76W26 OX OX OX OX
Copper - C1TRAP10AD2 76W27 OX OX OX OX
Conventional Fin/Tube Condenser Coil (replaces Environ
Coil System)
Factory O O O
Corrosion Protection Factory O O O O
Drain Pan Overow Switch E1SNSR71AD1 68W88 OX OX OX OX
Refrigerant Type R-410A O O O O
Service Valves (not for Environ™ Coil System or Humiditrol
®
equipped units)
Factory O O O O
HEATING SYSTEM
Bottom Gas Piping Kit C1GPKT01B-01 54W95 OX OX OX OX
Combustion Air Intake Extensions T1EXTN10AN1 19W51 X X X X
Gas Heat Input 130,000 Btuh Factory O O O O
180,000 Btuh Factory O O O O
240,000 Btuh Factory O O O O
Low Temperature Vestibule Heater 208/230V-3ph - C1LTVH10B-2Y 13X63 OX OX OX OX
460V - C1LTVH10B-2G 13X64 OX OX OX OX
575V - C1LTVH10B-2J 13X65 OX OX OX OX
LPG/Propane Conversion Kits Standard Heat - C1PROP23BS1 14N22 X X X X
Medium Heat - C1PROP22BS1 14N23 X X X X
High Heat - C1PROP21BS1 14N25 X
X X X
Stainless Steel Heat Exchanger Factory O O O O
Vertical Vent Extension Kit C1EXTN2021 42W16 X X X X
BLOWER - SUPPLY AIR
Blower Option CAV (Constant Air Volume) Factory O O O O
MSAV
®
(Multi-Stage Air Volume) supply air blower option (With VFD Bypass Control) Factory O O O O
MSAV
®
(Multi-Stage Air Volume) supply air blower option (Without VFD Bypass Control) Factory O O O O
Motors - Constant Air
Volume (CAV)
Belt Drive (standard efciency) - 2 hp Factory O O O O
Belt Drive (standard or high efciency) - 3 hp Factory O O O O
Belt Drive (standard efciency) - 5 hp Factory O O O O
Motors - MSAV
®
Multi-Stage Air Volume
Belt Drive (standard efciency) - 2 hp Factory O O O O
Belt Drive (standard efciency) - 3 hp Factory O O O O
Belt Drive (standard efciency) - 5 hp Factory O O O O
Drive Kits
See Blower Data Tables for selection
Kit #1 590-890 rpm Factory O O O O
Kit #2 800-1105 rpm Factory O O O O
Kit #3 795-1195 rpm Factory O O O O
Kit #4 730-970 rpm Factory O O O O
Kit #5 940-1200 rpm Factory O O O O
Kit #6 1015-1300 rpm Factory O O O O
Kit #7 730-970 rpm Factory O O O O
Kit #8 940-1200 rpm Factory
O O O O
Kit #9 1015-1300 rpm Factory O O O O
Kit #10 900-1135 rpm Factory O O O O
Kit #11 1040-1315 rpm Factory O O O O
Kit #12 1125-1425 rpm Factory O O O O
Blower Belt Auto-Tensioner Factory O O O O
CABINET
Combination Coil/
Hail Guards
Furnish Environ™ Coil System - C1GARD52B-1 13T05 X X X
Optional Conventional Fin/Tube Condenser Coil - E1GARD51B-1 13T04 X X X
Furnished Conventional Fin/Tube Condenser Coil System - C1GARD52B-1 13T05 X
Horizontal Discharge Kit K1HECK00B-1 51W25 X X X X
Return Air Adaptor Plate (for LC/LG/LH and TC/TG/TH unit replacement) C1CONV10B-1 54W96 OX OX OX OX
NOTE - Catalog and model numbers shown are for ordering eld installed accessories.
OX - Congure To Order (Factory Installed) or Field Installed
O = Congure To Order (Factory Installed)
X = Field Installed