Page 2
SPECIFICATIONS
Gas
Heating
Performance
Model No. ML180UH045E36A ML180UH070E36A ML180UH070E36B ML180UH090E48B
Model No. - Low Nox ML180UH045XE36A ML180UH070XE36A ML180UH070XE36B ML180UH090XE48B
1
AFUE 80% 80% 80% 80%
Input - Btuh 44,000 66,000 66,000 88,000
Output - Btuh 36,000 53,000 53,000 72,000
Temperature rise range - °F 15 - 45 40 - 70 40 - 70 35 - 65
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0 3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
High Static - in. w.g. 0.50 0.50 0.50 0.50
Connections
in.
Flue connection - in. round 4 4 4 4
Gas pipe size IPS 1/2 1/2 1/2 1/2
Indoor
Blower
Wheel nom. dia. x width - in. 10 x 8 10 x 10 10 x 10 10 x 10
Motor Type DC Brushless DC Brushless DC Brushless DC Brushless
Motor output - hp 1/2 1/2 1/2 3/4
Tons of add-on cooling 1.5 - 3 1.5 - 3 1.5 - 3 2.5 - 4
Air Volume Range - cfm 350 - 1380 625 - 1435 395 - 1415 750 - 1785
Electrical
Data
Voltage 120 volts - 60 hertz - 1 phase
Blower motor full load amps 6.8 6.8 6.8 8.4
Maximum overcurrent protection 15 15 15 15
Shipping Data lbs. - 1 package 111 111 127 142
SPECIFICATIONS
Gas
Heating
Performance
Model No. ML180UH090E60C ML180UH110E60C ML180UH135E60D
Model No. - Low Nox - - - ML180UH110XE60C - - -
1
AFUE 80% 80% 80%
Input - Btuh 88,000 110,000 132,000
Output - Btuh 72,000 90,000 107,000
Temperature rise range - °F 30 - 60 35 - 65 30 - 60
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
High Static - in. w.g. 0.50 0.50 0.50
Connections
in.
Flue connection - in. round 4 4 4
Gas pipe size IPS 1/2 1/2 1/2
Indoor
Blower
Wheel nom. dia. x width - in. 11-1/2 x 10 11-1/2 x 10 11 x 11
Motor Type DC Brushless DC Brushless DC Brushless
Motor output - hp 1 1 1
Tons of add-on cooling 3 - 5 3 - 5 3.5 - 5
Air Volume Range - cfm 990 - 2290 920 - 2315 1140 - 2495
Electrical
Data
Voltage 120 volts - 60 hertz - 1 phase
Blower motor full load amps 10.9 10.9 10.9
Maximum overcurrent protection 15 15 15
Shipping Data lbs. - 1 package 152 160 178
NOTE - Filters and provisions for mounting are not furnished and must be eld provided.
1
Annual Fuel Utilization Eciency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.