19.6.1. Test Run Instructions
YoushouldperformtheTestRunforatleast30minutes.
1. Connectpowertotheunit.
2. PresstheON/OFFbuttonontheremotecontrollertoturniton.
3. Pressthemodebuttontoscrollthroughthefollowingfunctions,oneatatime:
COOL-Selectlowestpossibletemperature.
HEAT-Selecthighestpossibletemperature.
4. Leteachfunctionrunfor5minutes,andperformthefollowingchecks:
19.6.2. Before Test Run
Table 5. Test Run Checklist
Checks Pass Fail
Noelectricalleakage
Unitisproperlygrounded
All electrical terminals properly covered
Indoor and outdoor units are solidly installed
Allpipeconnectionpointsdonotleak
Waterdrainsproperlyfromdrainhose
All piping is properly insulated
UnitperformsCOOLfunctionproperly
UnitperformsHEATfunctionproperly
Indoor unit louvers rotate properly
Indoor unit responds to remote controller
19.7. Double-Check Pipe Connections
Duringoperation,thepressureoftherefrigerantcircuitwillincrease.Thismayrevealleaksthatwerenotpresentduringyour
initialleakcheck.TaketimeduringtheTestRuntodouble-checkthatallrefrigerantpipeconnectionpointsdonothaveleaks.
Usingremotecontrol,returnunittothenormaloperatingtemperature.
Usinginsulationtape,wraptheindoorrefrigerantpipeconnectionsthatyouleftuncoveredduringtheindoorunit
installation process.
19.8. Ambient Temperature is Below 63°F (17°C)
Youcan’tusetheremotecontrollertoturnontheCOOL
functionwhentheambienttemperatureisbelow17°C.
Inthisinstance,youcanusetheMANUALCONTROL
buttontotesttheCOOLfunction.
Liftthefrontpaneloftheindoorunit,andraiseit
untilitclicksinplace.
TheMANUALCONTROLbuttonislocatedon
theright-handsideoftheunit.Pressit2timesto
selecttheCOOLfunction.
PerformTestRunasnormal.
Manual control
button

Table of Contents

Other manuals for Lennox MLA012S4S-1P

Questions and Answers:

Lennox MLA012S4S-1P Specifications

General IconGeneral
BrandLennox
ModelMLA012S4S-1P
CategoryAir Conditioner
LanguageEnglish

Summary

Single and Multiple Zone Outdoor Units Specifications

Indoor Unit Specifications and Diagrams

M22A, M33A and M33B Cassette Non-Ducted Indoor Units

Covers model identification, specifications, dimensions, and clearances for cassette indoor units.

MMDA Ducted Indoor Units

Details model identification, specifications, blower data, dimensions, and clearances for ducted units.

MWMA and MWMB Wall Mounted Indoor Units

Provides model identification, specifications, dimensions, and clearances for wall-mounted indoor units.

MCFA and MCFB Ceiling / Floor Indoor Units

Covers model identification, specifications, dimensions, and clearances for ceiling/floor indoor units.

System Combinations and Piping

Refrigeration Pipe Work

Details refrigerant cycle diagrams and piping limitations for single and multi-zone systems.

Electrical, Start-Up, and Troubleshooting

Indoor Unit Diagrams

Presents wiring diagrams for various indoor unit types including MWMA, M22A, M33A, MMDA, MCFA/MCFB.

Quick Reference Guide - Error Codes

Lists and explains common error codes for indoor and outdoor units, with basic troubleshooting.

Troubleshooting Outdoor Unit Error Codes

Provides detailed troubleshooting flowcharts for various outdoor unit error codes (E0, E2, E3, etc.).

Troubleshooting Indoor Unit Error Codes

Offers troubleshooting steps for common indoor unit error codes such as CP, E0, E1, E3, E4, E5, EC, EE.

Related product manuals