EasyManuals Logo
Home>Lennox>Air Conditioner>MLA018S4S-1P

Lennox MLA018S4S-1P User Manual

Lennox MLA018S4S-1P
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
52
10. Power Wiring for Outdoor and Indoor Units (Diagrams)
CAUTION
Thisunitmustbeproperlygroundedandprotectedbyacircuitbreaker.Thegroundwirefortheunitmustnotbeconnected
toagasorwaterpipe,alightningconductororatelephonegroundwire.
Do not connect power wires to the outdoor unit until all other wiring and piping connections have been com-
pleted.
Install all wiring at least 3 feet (1 m) away from televisions, radios or other electronic devices in order to avoid the
possibility of interference with the unit operation.
Do not install the unit near a lighting appliance that includes a ballast. The ballast may affect remote control
operation.
WARNING
Isolate the power supply before accessing unit electrical terminals.
Install unit so that unit disconnect is accessible.
Follow all local and national codes, as well as this installation instruction, during installation. Do NOT overload
electricalcircuit,asthismayleadtofailureandpossiblere.
Usespeciedwiringandcabletomakeelectricalconnections.Clampcablessecurelyandmakesurethatcon-
nections are tight to avoid strain on wiring. Insecure wiring connections may result in equipment failure and risk
ofre.Wiringmustbeinstalledsothatallcoverplatescanbesecurelyclosed.
IntheU.S.A.,wiringmustconformwithcurrentlocalcodesandthecurrentNationalElectricCode(NEC).InCanada,wiring
mustconformwithcurrentlocalcodesandthecurrentCanadianElectricalCode(CEC).
Refertounitnameplateforminimumcircuitampacityandmaximumover-currentprotectionsize.
Allindoorunitsarepoweredbytheoutdoorunit.
Communicationwiringisdeterminedbytheindoorunitsize.Indoorunits30kandbelowuseonestranded
4-conductorwiretoprovidepowerandcommunication.
Indoorunits36kandaboveuseonestranded3-conductorwiretoprovidepowerandonestranded2-conductorwire
to provide communication.
NOTE: Multi-zone systems use indoor units sizes 24k and below.
Makeallelectricalpowerwiringconnectionsattheoutdoorunit.
Useminimumof18GAstrandedwiring.
Connectwiringfromoutdoorunittoindoorunit.
Refertounitnameplateforratedvoltage.
Besuretoreattachallelectricalboxcoversafterconnectionsarecomplete.
FollowNEC/CECstandardsandalllocalandstatecodesduringwiringinstallation.

Table of Contents

Other manuals for Lennox MLA018S4S-1P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MLA018S4S-1P and is the answer not in the manual?

Lennox MLA018S4S-1P Specifications

General IconGeneral
BrandLennox
ModelMLA018S4S-1P
CategoryAir Conditioner
LanguageEnglish

Related product manuals