EasyManuals Logo
Home>Lennox>Air Conditioner>MLA030S4M-*P

Lennox MLA030S4M-*P User Manual

Lennox MLA030S4M-*P
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
94
19.6.1. Test Run Instructions
YoushouldperformtheTestRunforatleast30minutes.
1. Connectpowertotheunit.
2. PresstheON/OFFbuttonontheremotecontrollertoturniton.
3. Pressthemodebuttontoscrollthroughthefollowingfunctions,oneatatime:
COOL-Selectlowestpossibletemperature.
HEAT-Selecthighestpossibletemperature.
4. Leteachfunctionrunfor5minutes,andperformthefollowingchecks:
19.6.2. Before Test Run
Table 5. Test Run Checklist
Checks Pass Fail
Noelectricalleakage
Unitisproperlygrounded
All electrical terminals properly covered
Indoor and outdoor units are solidly installed
Allpipeconnectionpointsdonotleak
Waterdrainsproperlyfromdrainhose
All piping is properly insulated
UnitperformsCOOLfunctionproperly
UnitperformsHEATfunctionproperly
Indoor unit louvers rotate properly
Indoor unit responds to remote controller
19.7. Double-Check Pipe Connections
Duringoperation,thepressureoftherefrigerantcircuitwillincrease.Thismayrevealleaksthatwerenotpresentduringyour
initialleakcheck.TaketimeduringtheTestRuntodouble-checkthatallrefrigerantpipeconnectionpointsdonothaveleaks.
Usingremotecontrol,returnunittothenormaloperatingtemperature.
Usinginsulationtape,wraptheindoorrefrigerantpipeconnectionsthatyouleftuncoveredduringtheindoorunit
installation process.
19.8. Ambient Temperature is Below 63°F (17°C)
Youcan’tusetheremotecontrollertoturnontheCOOL
functionwhentheambienttemperatureisbelow17°C.
Inthisinstance,youcanusetheMANUALCONTROL
buttontotesttheCOOLfunction.
Liftthefrontpaneloftheindoorunit,andraiseit
untilitclicksinplace.
TheMANUALCONTROLbuttonislocatedon
theright-handsideoftheunit.Pressit2timesto
selecttheCOOLfunction.
PerformTestRunasnormal.
Manual control
button

Table of Contents

Other manuals for Lennox MLA030S4M-*P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MLA030S4M-*P and is the answer not in the manual?

Lennox MLA030S4M-*P Specifications

General IconGeneral
BrandLennox
ModelMLA030S4M-*P
CategoryAir Conditioner
LanguageEnglish

Related product manuals