The unit base should be elevated above the depth of
average snows as illustrated in “Figure 6. Outdoor Unit
on Brackets above Snow Line” on page 6
In heavy snow areas, do not place the unit where drift-
ing will occur as illustrated in “Figure 7. Outdoor Unit
Air Flow Obstructed by Snow” on page 6
Carefully consider how to manage defrost water dis-
posal to prevent ice from blocking walkways or creat-
ing a safety hazard near the outdoor unit as illustrated
in “Figure 8. Avoid Defrost Water Ice Hazard” on page
6
12 in
305 mm
Air Inlet
Air Outlet
24 in
610 mm
Side View
Front View
Protective canopy
Protective canopy
Pedestal
(stand)
Pedestal
(stand)
Figure 5. Outdoor Unit on Pedestal (Stand) and
Protective Canopy
Air Inlet
Air Outlet
Figure 6. Outdoor Unit on Brackets above Snow
Line
Air Outlet
Air Inlet
12 in
305 mm
79 in
2007 mm
Figure 7. Outdoor Unit Air Flow Obstructed by
Snow
Figure 8. Avoid Defrost Water Ice Hazard
Prevailing Winds
Normally wind bafes are not required for a outdoor unit.
However, in order to maximize reliability and performance,
the following best practices should be followed.
If unit coil cannot be installed away from prevailing winter
winds, some method of protecting the coil is recommended.
However, minimum clearances as reference in “Figure 3.
Outdoor Unit Clearances - Inches (mm)” on page 4
must be observed at all times.
Common application examples are:
When prevailing winds are from the air inlet side, then
position the wind barrier a minimum of 12 inches (305
mm) from the unit as illustrated in “Figure 9. Wind Bar-
rier”
When prevailing wind is into the discharge side, then
position the wind barrier a minimum 79 inches (2007
mm) from the front of the unit as illustrated in “Figure
9. Wind Barrier”
Outdoor unit can be installed in a dog house style shel-
ter as illustrated in”Figure 10. Dog House-Style Shel-
ter”
Outdoor unit can be installed in a alcove or under a
roof overhang as illustrated in “Figure 11. Unit installed
in Alcove”

Other manuals for Lennox MPA018S4M-*P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MPA018S4M-*P and is the answer not in the manual?

Lennox MPA018S4M-*P Specifications

General IconGeneral
BrandLennox
ModelMPA018S4M-*P
CategoryAir Conditioner
LanguageEnglish

Related product manuals