19. Start-Up
19.1. Adding Refrigerant - Single-Zone Systems
Theoutdoorunitisfactory-chargedwithrefrigerant.Calculatetheadditionalrefrigerantrequiredaccordingtothediameter
andthelengthoftheliquidpipebetweentheoutdoorunitandindoorunitconnections.
Besuretoaddtheproperamountofadditionalrefrigerant.Failuretodosomayresultinreducedperformance.
NOTE: Interconnecting pipe work between outdoor and indoor units must be 10 ft. or longer.
NOTE: Do not remove refrigerant for line lengths less than 25 ft. R-410A is a blended refrigerant. If you must remove
charge, it is necessary to remove the entire charge and weigh in the new charge.
Table 1. Adding Refrigerant
System Size (KBtu)
Pipe Length Amount of Refrigerant to add
09 >25 ft. (7.5m) 0.161oz/ft(15g/m)
12 >25 ft. (7.5m) 0.161oz/ft(15g/m)
18 >25 ft. (7.5m) 0.161oz/ft(15g/m)
24 >25 ft. (7.5m) 0.322oz/ft(30g/m)
36 >25 ft. (7.5m) 0.322oz/ft(30g/m)
48 >25 ft. (7.5m) 0.322oz/ft(30g/m)
19.2. Adding Refrigerant - Multi-Zone Systems
Theoutdoorunitisfactory-chargedwithrefrigerant.Calculatetheadditionalrefrigerantrequiredaccordingtothelengthof
theliquidpipe(oneway)betweentheoutdoorunitandindoorunitconnections.
Besuretoaddtheproperamountofadditionalrefrigerant.Failuretodosomayresultinreducedperformance.
NOTE: Interconnecting pipe work between outdoor and indoor units must be 10 ft. or longer.
NOTE: Do not remove refrigerant for line lengths less than 25 ft. R-410A is a blended refrigerant. If you must remove
charge, it is necessary to remove the entire charge and weigh in the new charge.
Table 2. Adding Refrigerant
System
Pre-charge
Pipe Length
Amount of Refrigerant to add
Two-port 50 ft. (15 m)
0.16oz((L1ft+L2ft)-50ft)
0.005kg((L1m+L2m)-15m)
Three-port 75 ft. (23 m)
0.16oz((L1ft+L2ft+L3ft)-75ft)
0.005kg((L1m+L2m+L3m)-23m)
Four-port 100 ft. (30 m)
0.16oz((L1ft+L2ft+L3ft+L4ft)-100ft)
0.005kg((L1m+L2m+L3m+L4m)-30m)
Five-port 125 ft. (38 m)
0.16oz((L1ft+L2ft+L3ft+L4ft+L5ft)-125ft)
0.005kg((L1m+L2m+L3m+L4m+L5m)-38m)

Table of Contents

Other manuals for Lennox MPB030S4M-*P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MPB030S4M-*P and is the answer not in the manual?

Lennox MPB030S4M-*P Specifications

General IconGeneral
BrandLennox
ModelMPB030S4M-*P
CategoryAir Conditioner
LanguageEnglish

Related product manuals