Page 2
XP21
I. OVERVIEW
Model Number identification
P 21 XXX− −
Unit Type
P = Heat Pump
Series
Nominal Cooling Capacity
024 = 2 tons
036 = 3 tons
048 = 4 tons
060 = 5 tons
Minor Revision Number
230
Voltage
230 = 208/230V−1ph−60hz
Refrigerant Type
X = R−410A
X
−02
Typical Serial Number Identification
8 09 C
Year Code
08 = 2008
09 = 2009
10 = 2010
Month Code
A = January
B = February
C = March
05716
5 (or 6) Digit Unique Number
Location Code
19 = Saltillo, Mexico
58 = Marshalltown, IA
5
Specifications
Model Number
Unit Outdoor Fan
Sound Rating Number
(dB)
1
Factory Refrigerant
Charge
2
Number of Blades Diameter − inches.
XP21−024−230−01, −02, −03, −04, −05 67 11 lbs. 0 oz. 5 26.1
Model Number
Unit Outdoor Fan
Sound Rating Number
(dB)
1
Factory Refrigerant
Charge
2
Number of Blades Diameter − inches.
XP21−036−230−01, −02, −03, −04 72 11 lbs. 0 oz. 5 26.1
Model Number
Sound Rating Number
(dB)
1
Factory Refrigerant
Charge
2
Number of Blades Diameter − inches.
XP21−048−230−01, −02, −03 73 14 lbs. 0 oz. 5 26.1
XP21−048−230−04 73 13 lbs. 0 oz. 5 26.1
Model Number
Sound Rating Number
(dB)
1
Factory Refrigerant
Charge
2
Number of Blades Diameter − inches.
XP21−060−230−01, −02, −03 73 14 lbs. 4 oz. 5 26.1
XP21−060−230−04 73 13 lbs. 2 oz. 5 26.1
1
Tested according to AHRI Standard 270−2008 test conditions.
2
Refrigerant charge sufficient for 15 feet length of refrigerant lines.