TS 6 to 20 Ton R−410A Air Conditioners / Page 10
ARI RATINGS
Gross
Cooling
Capacity
Btuh
Net
Cooling
Capacity
Btuh
EER
Integrated
Part
Load
Value
Indoor Coil or
Air Handler
Expansion
Device
TSA072S4S 6 TON
Air Handlers
68,300 66,000 10.2 − − −
2
CBX32M−060 (Multi−Position) Factory TXV
71,800 69,000 10.2 − − −
3
CBX27UH−060 (Up−Flow / Horizontal) Factory TXV
72,700 71,000 11.2 − − −
3
TAA072S4S (Up−Flow / Horizontal) Factory TXV
Up−Flow Indoor Coils
71,800 69,000 10.5 − − −
2
CX34−62D−6F Factory TXV
75,000 72,000 10.8 − − − (2) CX34−43B/C−6F Factory TXV
Horizontal Indoor Coils
70,100 68,000 10.3 − − −
2
CH33−62D−2F
1
91M02
TSA090S4S 7.5 TON
Air Handlers
91,800 89,000 11.2 − − −
3
TAA090S4S (Up−Flow / Horizontal) Factory TXV
95,000 92,000 11.3 − − −
3
TAA120S4D (Up−Flow / Horizontal) Factory TXV
Up−Flow Indoor Coils
92,200 89,000 10.8 − − −
2
(2) CX34−49C−6F Factory TXV
Down−Flow Indoor Coils
90,800 87,000 10.6 − − −
2
(2) CR33−50/60C−F
1
91M02
Horizontal Indoor Coils
92,800 89,000 10.8 − − −
2
(2) CH33−49C−2F
1
91M02
(2) TSA090S4S (2) 7.5 TON
Air Handlers
178,000 172,000 11.0 12.2
3
TAA180S4D (Up−Flow / Horizontal) Factory TXV
TSA120S4S 10 TON
Air Handlers
117,100 113,000 11.2 − − −
3
TAA120S4D (Up−Flow / Horizontal) Factory TXV
Up−Flow Indoor Coils
115,500 111,000 10.9 − − −
2
(2) CX34−62D−6F Factory TXV
Down−Flow Indoor Coils
111,400 107,000 10.6 − − −
2
(2) CR33−50/60C−2F
1
91M02
Horizontal Indoor Coils
116,000 111,000 10.8 − − −
2
(2) CH33−62D−2F
1
91M02
(2) TSA120S4S (2) 10 TON
Air Handlers
231,800 222,000 11.0 12.0
3
TAA240S4D (Up−Flow / Horizontal)
TSA120S4D (DUAL CIRCUIT) 10 TON
Air Handlers
119,700 115,000 11.2 11.8
3
TAA120S4D (Up−Flow / Horizontal) Factory TXV
Up−Flow Indoor Coils
115,900 111,000 10.8 11.3 (2) CX34−60D−6F Factory TXV
116,900 112,000 10.9 11.4 (2) CX34−62D−6F Factory TXV
Down−Flow Indoor Coils
111,700 107,000 10.7 11.1
2
(2) CR33−50/60C−2F
1
91M02
Horizontal Indoor Coils
116,100 111,000 10.8 11.2
2
(2) CH33−62D−2F
1
91M02
NOTES − Net capacity includes indoor blower motor heat deduction. Gross capacity does not include indoor blower motor heat deduction.
Units with capacity of 65,000 Btuh or greater are certified in accordance with the ULE certification program which is based on ARI Standard 340/360: 95_F outdoor air
temperature, 80_F db/67_F wb entering evaporator air (minimum external duct static pressure) with 25 ft. of connecting refrigerant lines.
1
Factory installed RFC or expansion valve on indoor unit MUST be replaced with expansion valve kit (ordered separately).
2
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (58M81) is recommended for field installation.
3
Blower control must be set for a time−off blower delay.