XC16 - 2 to 5 Ton Heat Pump / Page 5
SPECIFICATIONS
General
Data
Model No. XC16-024 XC16-036 XC16-048 XC16-060
Nominal Tonnage 2 3 4 5
Connections
(sweat)
Liquid line (o.d.) - in. 3/8 3/8 3/8 3/8
Suction line (o.d.) - in. 3/4 7/8 7/8 1-1/8
Refrigerant
1
R-410A charge furnished 7 lbs. 6 oz. 8 lbs. 8 oz. 11 lbs. 4 oz. 14 lbs. 2 oz.
Outdoor
Coil
Net face area - sq. ft. Outer coil 21.00 24.5 21.00 24.93
Inner coil - - - - - - 20.27 24.14
Tube diameter - in. 5/16 5/16 5/16 5/16
No. of rows 1 1 2 2
Fins per inch 26 26 22 22
Outdoor
Fan
Diameter - in. 22 22 22 26
No. of blades 4 4 4 3
Motor hp 1/6 1/6 1/4 1/3
Cfm 3230 3260 3955 4380
Rpm 840 840 835 850
Watts 215 220 320 280
Shipping Data - lbs. 1 pkg. 230 249 268 323
ELECTRICAL DATA
Line voltage data - 60hz
4
230V-1ph
4
230V-1ph
4
230V-1ph
4
230V-1ph
2
Maximum overcurrent protection (amps) 20 35 45 60
3
Minimum circuit ampacity 13.6 22.0 28.2 33.9
Compressor Rated load amps 10.3 16.7 21.2 25.9
Locked rotor amps 52 82 96 118
Power factor 0.98 0.99 0.99 0.99
Outdoor Fan
Motor
Full load amps 1.1 1.1 1.7 1.8
Locked Rotor amps 2.1 2.1 3.1 2.9
OPTIONAL ACCESSORIES - must be ordered extra
ComfortSense
®
7000 Thermostat Y2081
Outdoor Temperature Sensor - for
ComfortSense 7000 Thermostat
X2658
Compressor Hard Start Kit - Required in
applications with less than 230V
10J42
81J69
Compressor Low Ambient Cut-Off 45F08
Compressor Time-Off Control 47J27
Freezestat 3/8 in. tubing 93G35
5/8 in. tubing 50A93
Indoor Blower Off Delay Relay 58M81
Indoor Blower Speed Relay 40K58
Low Ambient Kit 34M72
Refrigerant
Line Sets
L15-41-20 L15-41-40
L15-41-30 L15-41-50
L15-65-30 L15-65-40
L15-65-50
Field Fabricate
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufcient for 15 ft. length of refrigerant lines.
2
HACR type breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
4
Hard start kit is required in applications where the supply voltage is less than 230V.