Page 2
SPECIFICATIONS
General
Dt
Model No. XP14−018 XP14−024 XP14−030 XP14−036 XP14−042 XP14−048 XP14−060
Data
Nominal Tonnage 1.5
2 2.5 3 3.5 4 5
Connections
(t)
Liquid line o.d. − in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
(sweat)
Vapor line o.d. − in. 3/4
3/4 3/4 7/8 7/8 7/8 1-1/8
1
Refrigerant HFC−410A charge furnished 8 lbs.
4 oz.
8 lbs.
0 oz.
7 lbs.
2 oz.
9 lbs.
12 oz.
12 lbs.
7 oz.
12 lbs.
10 oz.
16 lbs.
0 oz.
Outdoor
Cil
Net face area
ft
Outer coil 13.30 13.30 15.21 19.39 24.93 24.93 29.09
Coil sq. ft.
Inner coil 12.60
12.60 14.50 18.77 24.13 24.13 28.16
Tube diameter − in. 5/16 5/16 5/16 5/16 5/16 5/16 5/16
No. of rows 2 2 2 2 2 2 2
Fins per inch 22 22 22 22 22 22 22
Outdoor
F
Diameter in. 18 18 18 26 26 26 26
Fan
No. of Blades 3
3 3 4 4 4 4
Motor hp 1/10 1/10 1/10 1/3 1/3 1/3 1/3
Cfm 2165 2165 2232 4090 4347 4347 4550
Rpm 1015 1015 1035 844 843 843 830
Watts 171 171 165 299 299 299 307
Shipping Data − lbs. 1 package 194 194 205 263 317 319 345
ELECTRICAL DATA
Line voltage data − 60 hz − 1ph 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V
2
Maximum overcurrent protection (amps) 20 30 30 30 40 50 60
3
Minimum circuit ampacity 11.9 17.5 17.0 19.4 24.2 29 34.8
Compressor
Rated Load Amps
8.97 13.46 13.1 14.1 17.94 21.79 26.41
p
Locked Rotor Amps
48 58 64 77 112 117 134
Power Factor
0.96 0.98 0.98 0.99 0.94 0.95 0.98
Outdoor
FMt
Full Load Amps
0.70 0.70 0.70 1.8 1.8 1.8 1.8
Fan Motor
Locked Rotor Amps
1.4
1.4 1.4 2.9 2.9 2.9 2.9
OPTIONAL ACCESSORIES − must be ordered extra
Compressor Crankcase Heater
93M04
p
Factory
Compressor Hard Start Kit
10J42
p
81J69
Compressor Low Ambient Cut−Off 45F08
Freezestat
3/8 in. tubing 93G35
5/8 in. tubing 50A93
Indoor Blower Off Delay Relay 58M81
4
Low Ambient Kit 54M89
Mild Weather Kit 33M07
Monitor Kit − Service Light 76F53
Outdoor
Th t t Kit
Thermostat 56A87
Thermostat Kit
Mounting Box 31461
Refrigerant
Line Sets
L15−41−20
L15−41−30
L15−41−40
L15−41−50
e Sets
L15−65−30 L15−65−40
L15−65−50
Field Fabricate
NOTE − Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufficient for 15 ft. length of refrigerant lines.
2
HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
4
Crankcase Heater and Freezestat are recommended with Low Ambient Kit.