XP16
Electrical Data
208/230V−60 Hz−1 Ph
Model Number
Unit Compressor Condenser Fan
Maximum
Over−
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated Load
Amps (RLA)
Locked
Rotor
Amps
(LRA)
Motor
HP
Motor
Type
Nominal
RPM
Full Load
Amps (FLA)
Locked Rotor
Amps (LRA)
XP16−024−230−01 20 14.0 10.25 52.0 1/10 PSC 1075 0.7 1.4
XP16−024−230−03 20 14.0 10.25 52.0 1/10 PSC 1075 0.7 1.4
XP16−024−230−04 20 14.0 10.25 52.0 1/10 PSC 1075 0.7 1.4
XP16−024−230−05 20 14.0 10.25 52.0 1/10 PSC 1075 0.7 1.4
208/230V−60 Hz−1 Ph
Model Number
Unit Compressor Condenser Fan
Maximum
Over−
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated Load
Amps (RLA)
Locked
Rotor
Amps
(LRA)
Motor
HP
Motor Type
Nominal
RPM
Full Load
Amps (FLA)
Locked Rotor
Amps (LRA)
XP16−036−230−01 35 22.0 16.67 82.0 1/6 PSC 825 1.1 2.1
XP16−036−230−02 35 22.0 16.67 82.0 1/6 PSC 825 1.1 2.1
XP16−036−230−03 35 22.0 16.67 82.0 1/6 PSC 825 1.1 2.1
XP16−036−230−04 35 22.0 16.67 82.0 1/6 PSC 825 1.1 1.87
XP16−036−230−05 35 22.5 16.67 82.0 1/4 PSC 825 1.7 3.1
208/230V−60 Hz−1 Ph
Model Number
Unit Compressor Condenser Fan
Maximum
Over−
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated Load
Amps (RLA)
Locked
Rotor
Amps
(LRA)
Motor
HP
Motor Type
Nominal
RPM
Full Load
Amps (FLA)
Locked Rotor
Amps (LRA)
XP16−048−230−01 45 28.2 21.15 96.0 1/4 PSC 825 1.7 3.1
XP16−048−230−02 45 28.2 21.15 96.0 1/4 PSC 825 1.7 3.1
XP16−048−230−03 45 28.2 21.15 96.0 1/4 PSC 825 1.7 3.1
XP16−048−230−04 45 28.2 21.15 96.0 1/4 PSC 825 1.7 3.1
XP16−048−230−05 45 28.2 21.15 96.0 1/3 PSC 825 1.8 2.9
208/230V−60 Hz−1 Ph
Model Number
Unit Compressor Condenser Fan
Maximum
Over−
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated Load
Amps (RLA)
Locked
Rotor
Amps
(LRA)
Motor
HP
Motor Type
3
Nominal
RPM
Full Load
Amps (FLA)
Locked Rotor
Amps (LRA)
XP16−060−230−01 55 33.9 25.64 118.0 1/3 PSC 825 1.8 2.9
XP16−060−230−02 60 33.9 25.87 118.0 1/3 PSC 825 1.8 2.9
XP16−060−230−03 60 33.9 25.87 118.0 1/3 PSC 825 1.8 2.9
XP16−060−230−04 60 33.9 25.87 118.0 1/3 PSC 825 1.8 2.9
XP16−060−230−05 60 35.1 25.87 118.0 1/3 VS
700
(1st Stage)
2.8 N/A
820
(2nd Stage)
1
HACR type circuit breaker or fuse.
2
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
3
PSC = permanent split capacitor motor (single speed); VS = variable speed.