35
E
7 Table of supported CVs
CV
Value /
Bit
Meaning
Ex-works
setting
1
1-127
Basic locomotive address. This number is used to call up
locomotives in the Digital plus by Lenz
®
system. The use of
range 1-99 is recommended for operation with
Digital plus by Lenz
®
devices.
When writing this CV, CV19 (multiple traction address) is
automatically deleted in the decoder and Bit 6 (use of extended
address) is deleted in CV29.
3
2
0-255
Minimum starting voltage
1
3
0-255
Starting delay
6
4
0-255
Braking delay
5
5
0-255
Maximum speed
254
6
0-255
Mid speed Vmid
48
7
-
Version number
79
8
-
Manufacturer’s ID
99
9
0-63
Repeat rate
77
17
192-231
Extended locomotive address, high-order byte
192
18
0-255
Extended locomotive address, low-order byte
100
19
1-99
Multiple traction address
0
28
Bit
RailCom configuration
3(dec)
1 (0)
1 channel 1 release for address broadcast
1
2 (1)
1 channel 2 release for data and command acknowledge
1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenz Digital Plus STANDARD PLUS V2 and is the answer not in the manual?

Lenz Digital Plus STANDARD PLUS V2 Specifications

General IconGeneral
BrandLenz
ModelDigital Plus STANDARD PLUS V2
CategoryMedia Converter
LanguageEnglish

Related product manuals