22
L
4.6 Additional terminals
Terminal
designation
Meaning
9+V
CC
= +15 V= stabilized. +V
CC
can be loaded externally with 15 mA.
12
Input current controller; R
i
» 10 k, U
iset
= 0... 10 V= (10 V
=
^
I
Amax
)
14 -V
CC
= -15 V= stabilized. -V
CC
can be loaded externally with 15 mA.
31 Output actual armature current. The output terminal 31 supplies an output voltage proportional
to the armature current. U
31
» 5 V corresponds to the rated controller current. This output can
be loaded with a maximum of 3 mA. The output resistance is R
i
= 1 k.
38
Freely assignable speed controller input
Terminal 38 leads to the summation point of the speed controller via R
i
» 50 k. The
permissible input voltage range is between -10 V and +10 V.
40
Output speed controller; R
i
» 200 .
Terminals 40 and 12 are connected internally via a resistor 2.2 k
(R812 on soldering posts, see chapter 2.2 "Dimensions").
Caution!
If an external set-value potentiometer is connected, this resistor must be removed.
Connection of a potentiometer to limit the current set-value:
4.7 Replacing the fuses
The fuses protect the controller from non-permissible operating
conditions. After the release of such a protective function, the
controller and the system must be checked for further faults before
replacing the fuses.
Remove the protective cover to replace the fuses.
Caution!
Removal of the protective cover and the replacement of the
fuses must only be carried out by qualified skilled personnel
when no voltage is applied.
Defective fuses must only be replaced by the prescribed type (see
chapter 2.1 "Controller-specific data").
The protective cover must be attached again after the fuses are
replaced.