6
L
2 Technical data
2.1 Controller-specific data
Type 481 482 483 484 485
Output power P
el
[kW] 10.5 23 46 92 115
Mains frequency f [Hz] 50...60
Mains voltage V
3L
[V] 340...460
Armature voltage V
A
460 V for V
3L
= 400 V (1.15 x V
3L
)
Armature current I
A
[A] 23 50 100 200 250
Field voltage V
F
0.9 x V
L1, L2 (N)
Max. field current I
F [A]
810
Rated master voltage V
LN
[V] 10...180
Rated tacho voltage V
TN
[V] 10...180
Operating ambient
temperature
T
u
[°C] 0...45
Set-value
potentiometer
Type
R
10k /1W
lin.
ER00322194
Field fuse
Type
F 101 FF16A/500V
EFSFF0160AWB
Electronics fuse
Type
F 102
F 103
F 104
F1A/450V
5 x 25
EFSF_0010AVF
Weight approx. m [kg] 4.5 5.5 8.5 10.5 13
Chassis type E 33.481__E 33.482__E 33.483__E 33.484__E 33.485__E