Zone 2 Balance:
Data Type: Unsigned 8 bit integer.
Maximum Value: 32
Conversion: 0 = Left
32 = Right
7.3.7 Get System Parameter Definition (MC-1)
This command is not supported by the MC-12.
7.3.8 Get System Parameter Values (MC-1)
This command is not supported by the MC-12.
7.3.9 Get Effect Definition by Id (MC-1)
This command is not supported by the MC-12.
7.3.10 Get Effect Parameter Definition (MC-1)
This command is not supported by the MC-12.
7.3.11 Get Effect Parameter Values (MC-1)
This command is not supported by the MC-12.
7.3.12 Get Custom Name (MC-12, MC-1)
Request to MC-12 for an effect definition. MC-12 will respond with “Custom Name Packet”.
7.3.12.1 Command Packet Description
Application Header:
Command DC_CMD_GET_CUST_NAME 0x2B
Data Count 0 0x00
Application Data:
N/A
7.3.12.2 Data Description
N/A
7.3.12.3 Custom Name Response Packet
Application Header:
Command DC_RESP_CUST_NAME 0x89
Data Count
Number of Characters in
CustomName + 1 nn
Application Data:
Data[0]- Data[DataCount-1] CustomName ch ch ch … 0x00
7.3.12.4 Data Description
CustomName:
Data Type: Null (0x00) terminated ASCII character string.