EasyManuals Logo
Home>LG>Dryer>DLE1101W

LG DLE1101W User Manual

LG DLE1101W
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
14
INSTALLATION INSTRUCTIONS
Clearances (cont.)
RECOMMENDED INSTALLATION SPACING FOR CABINET INSTALLATION
For cabinet installation with a door, minimum ventilation openings in the top of the cabinet are required.
*Required spacing
**For side or bottom venting,
2 inches (5.1 cm) spacing is allowed.
1"* (2,5 cm)
5
"**
(14 cm)
1/2
77
1/2
"
(196,8 cm)
3"* (7,6 cm)
6"*(15,2 cm)
3"* (7,6 cm)
27"
(68,6 cm)
1"
(2,5 cm)
1"
(2,5 cm)
24 in.
2*
(155 cm
2
)
48 in.
2*
(310 cm
2
)
Closet Door Vent
Requirements
Requisitos de ventilación
de la puerta del armario
(2,54 cm) (2,54 cm)
(7,6 cm)
(7,6 cm)
(7.6 cm)
(7.6 cm)
(68,6 cm)
(2.54 cm) (2.54 cm)(68.6 cm)
28
(73.4 cm)
7"* (17.8 cm)
7"* (17.8 cm)
5"*
(12.7 cm)
1"*
(2.5 cm)
(68.6 cm)
1"
(2.54 cm)
1"
(2.54 cm)
(2,54 cm) (2,54 cm)
(7,6 cm)
(7,6 cm)
(68,6 cm)
28
(73,4 cm)
7"* (17,8 cm)
7"* (17,8 cm)
5"*
(12,7 cm)
1"*
(2,5 cm)
27
"
(68,6 cm)
1"
(2,54 cm)
27
"
1"
(2,54 cm)
28
(73,4 cm)
7"* (17,8 cm)
7"* (17,8 cm)
5"*
(12,7 cm)
1"*
(2,5 cm)
(68,6 cm)
1"
(2,54 cm)
1"
(2,54 cm)
14
"
max.*
(35.6
cm)
21
1
/
4
"
(54 cm)
28
15
/
16
"
(73.4 cm)
50
1
/
4
"
(127.5 cm)
5"**
(12.7 cm)
40
3
/
16
"
(102 cm)
14
"
max.*
(35,6
cm)
21
1
/
4
"
(54 cm)
28
15
/
16
"
(73,4 cm)
50
1
/
4
"
(127,5 cm)
5"**
(12,7 cm)
40
3
/
16
"
(102 cm)
14
"
max.*
(35,6
cm)
21
1
/
4
"
(54 cm)
28
15
/
16
"
(73,4 cm)
50
1
/
4
"
(127,5 cm)
5"**
(12,7 cm)
40
3
/
16
"
(102 cm)
27
"
Leveling the dryer
w
WARNING


Failure to follow this
warning can cause serious injury or death.

Failure to follow this warning can
cause serious injury or death.
To ensure that the dryer provides optimal drying performance,
it must be level. To minimize vibration, noise, and unwanted
movement, the floor must be a perfectly level, solid surface.
1. Position the dryer in the final location. Place a level across the
top of the dryer.
All four leveling feet must rest solidly on the floor. Gently push
on the top corners of the dryer to make sure that the dryer does
not rock from corner to corner.
If you are installing the dryer on the optional pedestal, you must
use the leveling feet on the pedestal to level the dryer. The dryer
leveling feet should be fully retracted.
2. Use an adjustable wrench to turn the leveling feet. Turn
clockwise to raise the dryer or counterclockwise to lower it.
Raise or lower the leveling feet until dryer is level from side to
side and front to back.
Make sure that all 4 leveling feet are in firm contact with the floor.
Level
Leveling Feet
NOTE
Adjust the leveling feet only as far as necessary to level the
dryer. Extending the leveling feet more than necessary can
cause the dryer to vibrate.
3828EL2001J_en_120827.indd 14 2012.8.27 2:0:35 PM

Table of Contents

Other manuals for LG DLE1101W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG DLE1101W and is the answer not in the manual?

LG DLE1101W Specifications

General IconGeneral
Colorwhite
Dryer Capactity7.3 cubic feet
Number of Cycles9
Stackableno
Ventingyes
Temperature Controlyes
Control Typeelectronic
Delay Startno
Child Lockyes
Cycle Signalyes
Interior Lightyes
Drying Rackno
Moisture Sensor Optionyes
Steamno
Voltage240 volts
Current30 amperes
Weight and Dimensions IconWeight and Dimensions
Depth28.38 inches
Height40.16 inches
Width27 inches
Net Weight121.7 pounds

Related product manuals