Product Data
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
GENERAL DATA / SPECIFICATIONS
Type Single Zone Four-Way Ceiling Cassette
System (Model) (Indoor Unit / Outdoor Unit)
LC098HV4 (LCN098HV4 /
LUU097HV)
LC128HV4 (LCN128HV4 /
LUU127HV)
LC188HV4 (LCN188HV4 /
LUU189HV)
Ceiling Grille Model Number (Sold Separately) PT-QCHW0 / PT-UQC PT-QCHW0 / PT-UQC PT-QCHW0 / PT-UQC
Cooling Capacity (Min/Rated/Max) (Btu/h)
3,600 ~ 9,000 ~ 9,900 3,400 ~ 11,100 ~ 12,400 7,700 ~ 18,000 ~ 24,800
Cooling Power Input
1
(kW)
0.19 ~ 0.66 ~ 0.83 0.25 ~ 0.88 ~ 1.1 0.54 ~ 1.44 ~ 2.60
EER (OD 95°F)
13.65 12.6 12.5
SEER
20.2 19.4 20.5
Heating Capacity (Min/Rated/Max) (Btu/h)
4,400 ~ 11,000 ~ 12,100 2,800 ~ 14,000 ~ 15,500 6,500 ~ 18,500 ~ 23,400
Heating Power Input
1
(kW)
0.15 ~ 0.83 ~ 1.05 0.22 ~ 1.19 ~ 1.5 0.50 ~ 1.95 ~ 2.60
COP (OD 47°F)
3.88 3.44 2.78
HSPF
10.5 10.4 10
Rated Low Heating Capacity (Btu/h)
Outdoor 17°F (WB)/Indoor 70°F (DB)
7,000 9,100 12,700
Low COP (OD 17°F)
2.92 2.7 2.38
Maximum Heating Capacity (Btu/h)
Outdoor 17°F (WB)/Indoor 70°F (DB)
9,350 11,900 17,000
Outdoor 5°F (WB)/Indoor 70°F (DB)
8,250 10,500 15,000
Outdoor -4°F (WB)/Indoor 70°F (DB)
7,040 8,960 13,000
Power Supply V, Ø, Hz
2
208-230 / 1 / 60
Outdoor Unit Operating Range
Cooling (°F DB)
0 to +118
6
0 to +118
6
5 to +118
6
Heating (°F WB)
-4 to +64 -4 to +64 -4 to +64
Indoor Unit Operating Range
Cooling (°F WB)
57 to 77 57 to 77 57 to 77
Heating (°F DB)
59 to 81 59 to 81 59 to 81
Indoor Temperature Setting Range
Cooling (°F DB)
65 to 86 65 to 86 65 to 86
Heating (°F WB)
61 to 86 61 to 86 61 to 86
Unit Data
Refrigerant Type
3
R410A
Refrigerant Control
EEV
Indoor Unit Sound Pressure Level dB(A) (H/M/L)
4
36 / 33 / 30 38 / 35 / 32 41 / 39 / 36
Outdoor Unit Sound Pressure Level dB(A) (Cool/Heat)
4
47 / 51 49 / 52 48 / 52
Indoor Unit Net / Shipping Weight (lbs.)
31 / 37 31 / 37 31.5 / 40.0
Outdoor Unit Net / Shipping Weight (lbs.)
82 / 89 82 / 89 127.8 / 140.0
Grille Net / Shipping Weight (lbs.)
7 / 9 7 / 9 7 / 9
Power Wiring / Communications Cable (No. x AWG)
2
4 x 18 4 x 18 4 x 18
Compressor (Type x Qty.)
Twin Rotary x 1 Twin Rotary x 1 Twin Rotary x 1
Dehumidification Rate (pts./hr.)
1.6 2.47 3.3
Fan
Indoor Unit Type x Qty.
Turbo x 1
Outdoor Unit Type x Qty.
Axial x 1
Motor / Drive
Brushless Digitally Controlled / Direct
Airflow Rate
Indoor Unit (H / M / L [CFM])
300 / 265 / 230 335 / 283 / 247 460 / 424 / 388
Outdoor Unit (CFM)
988 988 2,048
Table 2: Four-Way Ceiling Cassette System General Data.
EEV: Electronic Expansion Valve, IDU: Indoor Unit, ODU: Outdoor Unit. This unit comes with a dry
helium charge.
This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft level
difference between outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF wet bulb
(WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
1
Power Input is rated at high speed.
2
All power wiring/communication cables from ODU to IDU are field supplied and are to be minimum 18
AWG, 4-conductor, stranded, shielded or unshielded (if shielded, must be grounded to chassis at ODU
only), and must comply with applicable local and national codes.
3
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy R410A
refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608 of CAA.
4
Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the
same in both cooling and heating mode. These values can increase due to ambient conditions during
operation.
5
Piping lengths are equivalent.
6
Cooling range can be extended from 0°F down to -4°F using the Low Ambient Wind Baffle Kit (sold
separately).
Piping
Liquid (in.) (Connection Size / Pipe Size)
1/4 / 1/4 1/4 / 3/8
Vapor (in.) (Connection Size / Pipe Size)
3/8 / 3/8 1/2 / 5/8
Indoor Unit Condensate Drain O.D. / I.D. (in.)
1-1/4 / 1 1-1/4 / 1
Additional Refrigerant Charge (oz./ft.)
0.22 0.43
Maximum Pipe Length (ft.)
66 164
Piping Length
5
(no additional refrigerant, ft.)
25 24.6
Maximum Elevation Difference (ft.)
49 98.4