Technical Data
74
850 mm
640 mm
600 mm
Net Weight : 55.9kg ,Opaque Door
57.4kg ,Glass(Cr) Door
Ensure you connect the dryer to the correct
electricity voltage. The ratings plate on your
dryer shows you what the voltage should be.
Electrical Requirements
Max. capacity : 9 kg
Allowable temperature : 5 ~ 35°C
Depth with door open : 1090mm
Volts Hertz Watts
230 V 50 Hz 1800
Ventilation Requirement
Alcove or
under counter
Closet
Ensure air flow of
112 cu.ft./min
through dryer
Closet door must have
2(louvered) openings,
each having a mini-
mum area of 60 sq.
inches (387 sq.cm),
located 3 inches (8 cm)
from bottom and top of
door.