7-1. BEFORE PERFORMING SERVICE
■
Be careful of electric shock when disconnecting parts while troubleshooting.
■
The voltage of each terminal is 120 V AC and DC when the unit is plugged in.
7-2. QC TEST MODE.
The washer must be empty and the controls must be in the off state.
1. Press the SPIN SPEED and SOIL LEVEL buttons simultaneously.
2. Press the Power button, while the above condition. Then buzzer will sound twice.
3. Press the Start/Pause button repeatedly to cycle through the test modes.
4. Alternate blinking of , and
7-3. HOW TO CHECK THE WATER LEVEL FREQUENCY
Press the Delay and Signal button simultaneously.
So, for example a display indicating 241: a Water level frequency of 241 x.1 kHz
= 24.1 kHz
The digits indicate the water level frequency ( x.1 kHz ).
sutatSyalpsiDtnioPkcehC
None T urns on all lamps and locks the door .
1 time T umble clockwise. rpm (40~50)
mpr.nipSdeepswoLsemit2
mpr.nipSdeepshgiHsemit3
4 times Inlet valve for prewash turns on. W ater level frequency (25~65)
5 times Inlet valve for main wash turns on. W ater level frequency (25~65)
6 times Inlet valve for hot water turns on. W ater level frequency (25~65)
7 times Inlet valve for bleach turns on. W ater level frequency (25~65)
8 times T umble counterclockwise. rpm (40~50)
9 times
Water temperature (Thermistor) Water temperature [°C]
10 times
Drain pump turns on.
Water level frequency (25~65)
11 times
Power off and unlock the door .
Turn off all lamps.
Number of times the
Start/Pause button is pressed