3.2.3 Force
The force function regulates the thrust and the speed of the automation.
Wait 25 seconds or press
again to quit.
Press the red LED (LEFT) switches on.
Press and to set the various force values.
Minimum
Maximum
LEDS ON FORCE VALUE
3.2.4 Obstacle detection
The automation is tted with an obstacle detection system: the automation inverts its movement when it strikes an obstacle during the opening and
closure phases.
Sensitivity regulation consists in greater or lesser rapidity in response to the obstacle.
1) D
uring the closure phase, if the control unit identies an obstacle, the automation inverts motion and performs complete opening. If the obstacle is
detected 3 times consecutively, the automation stops in a completely open position awaiting a
command.
2) If the control unit identies an obstacle, the automation performs a short reversal of motion, before stopping awaiting a command.
Wait 25 seconds or press
again to quit.
Press for 5 seconds, the red LED (LEFT) will light and
then switch off.
Press and to set the various obstacle detection values.
MINIMUM
MAXIMUM
LEDS ON OBSTACLE DETECTION
NO OBSTACLE DETECTION
FORCEFORCE
Press the force button (bottom left) and thePress the force button (bottom left) and the
left red led switches on.left red led switches on.
Press the + and - buttons to set the forcePress the + and - buttons to set the force
values.values.
The force value is indicated by the 5 leds atThe force value is indicated by the 5 led’s at
the top of the board.the top of the board.
Wait 25 seconds or press the force buttonWait 25 seconds or press the force button
again to quitagain to quit
OBSTACLE DETECTIONOBSTACLE DETECTION
The automation is fitted with an obstacle detection system. The automation inverts its movement when it strikes anThe automation is fi tted with an obstacle detection system. The automation inverts its movement when it strikes an
obstacle during the opening and closing phases.obstacle during the opening and closing phases.
1. During the closure phase, if the control unit identifies an obstacle, the automation inverts the motion and1. During the closure phase, if the control unit identifi es an obstacle, the automation inverts the motion and
performs a complete opening. If the obstacle is detected 3 times consecutively, the automation stops in the openperforms a complete opening. If the obstacle is detected 3 times consecutively, the automation stops in the open
position awaiting a command.position awaiting a command.
2. If the control unit identifies an obstacle on opening, the automation performs a short reversal of motion,2. If the control unit identifi es an obstacle on opening, the automation performs a short reversal of motion,
before stopping awaiting a command.before stopping awaiting a command.
Press the force button (bottom left)for 5Press the force button (bottom left)for 5
seconds and the left red led switches on andseconds and the left red led switches on and
then goes off.then goes off.
Press the + and - buttons to set the obstaclePress the + and - buttons to set the obstacle
detection values.detection values.
Wait 25 seconds or press the force buttonWait 25 seconds or press the force button
again to quitagain to quit
MINIMUM
MAXIMUM
LEDS ON OBSTACLE DETECTION
NO OBSTACLE DETECTION
secs
3.2 Functions
3.2.1 Courtesy light
The courtesy light function switches a light on during any automation movement.
The light remains on after the last manoeuvre for a 30-second period.
3.2.2 Deceleration in opening and closure
The automation decelerates in the final stretches of opening and closureo.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LIFE home integration RG1R UNI DL and is the answer not in the manual?

LIFE home integration RG1R UNI DL Specifications

General IconGeneral
BrandLIFE home integration
ModelRG1R UNI DL
CategoryControl Unit
LanguageEnglish

Related product manuals