© 2014 LifeSource Water Systems, Inc. 5
EQUIPMENT SPECIFICATIONS
PowerTAC™ Physical Properties
• Composition - Specially treated polymer
Operating Conditions
Can be used in continuous or intermittent operation. Install on
cold water supply only. No backwash required.
Water Chemistry Specifications
• pH 6.5 to 8.5
• Max. Hardness 75 grains (1300 ppm CaCO3)
• Temperature 41 to 140˚ F (5-60˚ C)
• Max. Chlorine <3 ppm
• Max. Iron, ferrous 0.3 mg/I
• Max. Manganese 0.05 mg/I
• Max. Copper 1.3 mg/I
• Oil & H2S Remove pre PowerTAC™
• Polyphosphates Remove pre PowerTAC™
Specifications
• Max. Dimensions 59.75” x 10”
• Max. Flow Rate 20 gpm
• Max. Temperature 100˚ F (37.8˚ C)
• Max. Pressure 100 PSI
Using ScaleSolver With Other Water Treatment Equipment
Both the SS-5544S and SS-5544E ScaleSolver systems are complete, self-contained, loaded with media and ready
to use. A simple inlet and outlet connection is all that is required for installation. Please review operating pressures,
temperatures and water chemistry limitations to ensure compatibility.
Due to the unique properties of ScaleSolver, there are some unique require-
ments for using ScaleSolver in conjunction with filtration or other forms of
water treatment.
1. ScaleSolver must be the last stage in the treatment chain. Do not
install any lters after ScaleSolver or before any devices for which
scale prevention is required. POU lters, e.g. carbon or RO are exempt
from this requirement.
2. Do not apply phosphate or any other antiscalant either before or after
ScaleSolver.
Template Assisted Crystallization is a
registered trademark of Next Filtration
Technologies, Inc.
®
Installation, Operation and Maintenance Manual
ScaleSolver SS-5544
®