© 2014 LifeSource Water Systems, Inc. 8
1. Place the system in the desired location.
2. Connect the Cold Water supply to the inlet of the
ScaleSolver system.
NOTE: The ScaleSolver operates in the upow mode
which is opposite of a conventional softener.
3. Place a bucket under the outlet port or run a line from the
outlet port to a drain.
4. Slowly open the supply valve (user supplied) to the
ScaleSolver . Allow the tank to ll with water. Close the
supply valve when a steady stream of water comes out of
the outlet port.
5. Connect the Outlet of the ScaleSolver system to the cold
water supply to the home.
6. Open the supply valve to the ScaleSolver system.
7. Open faucets downstream from the ScaleSolver system
to relieve any air.
8. Check for leaks. Repair as needed.
9. The system is now ready for service.
Bypass Valve Operation
IN Service Position Bypass Position
IN
Cold Water ScaleSolver Treated Water
OUT
INSTALLATION
®
Figure 1.
SS-5544S 1” shown with bypass assembly
Installation, Operation and Maintenance Manual
ScaleSolver SS-5544
®