Schwintek in-wall™ Slideout SyStem
winnebago induStrieS - ownerS manual
LIPPERTCOMPONENTS, INC.
Error codes
During operation when an error occurs the board will use the led’s to indicate where the problem
exists.
For motor specic faults the green led will blink 1 time for motor 1, and 2 times for motor 2. The red
led will blink from 2 to 9 times depending on the error code.
The error codes are as follows:
2 Battery drop out: Battery capacity low enough to drop below 6 volts while running
3 Low battery: Voltage below 8 volts at start of cycle
4 High battery: Voltage greater than 18 volts
5 Excessive motor current: High amperage, also indicated by 1 side of slide continually stalling.
6 Motor short circuit: Motor or wiring to motor has shorted out.
8 Hall signal not present: Encoder is not providing a signal. Usually a wiring problem.
9 Hall power short to ground: Power to encoder has been shorted to ground. Usually a wiring
problem.
When an error code is present, the board needs to be re-set. Energizing the extend/retract switch
resets the board. Energize the extend/retract switch again for normal operation.
WARNING!
DO NOT MOVE THE RV UNLESS THE MOTORS ARE PLUGGED IN!
revWNBG2