Rev: 06.25.20 Page 13 CCD-0001515
Preventative Maintenance
1. Check hydraulic fluid in reservoir every 12 months. If fluid is a clear, red color, do not change. If fluid is
milky, pink and murky, and not clear red in color, drain reservoir and add new fluid. Hydraulic fluid in
reservoir should be changed a minimum of every five years.
NOTE: Check the hydraulic fluid only when all the jacks are fully retracted.
NOTE: When checking the hydraulic fluid level, fill reservoir to within ¼" to ½" of fill spout.
2. Inspect and clean all power unit electrical connections every 12 months. If corrosion is evident, spray
connections with electrical contact cleaner.
3. Remove dirt and road debris from jacks as needed.
4. If jacks are extended for long periods of time, it is recommended to spray exposed jack rods with a dry
silicone lubricant every three months for protection. If the coach is located in a salty environment, it is
recommended to spray the rods every 4 - 6 weeks.
The coach should be supported at both front and rear axles with jack stands before working
underneath. Failure to do so may result in death, serious personal injury or severe product and/or
property damage.