2
ENGLISH (Original instructions)
SPECIFICATIONS
Model DTD134 DTD146
Machine screw 4 mm - 8 mm
Standard bolt 5 mm - 14 mm
Capacities
High tensile bolt 5 mm - 12 mm
No load speed (min
-1
) 0 - 2,400 0 - 2,300
Impacts per minute 0 - 3,200
Overall length 138 mm
Net weight
1.2 kg (with battery BL1415/BL1415N)
1.4 kg (with battery BL1430/BL1440)
1.3 kg (with battery BL1815/BL1815N/BL1820)
1.5 kg (with battery BL1830/BL1840/BL1850)
Rated voltage D.C.14.4 V D.C.18 V
• Due to our continuing program of research and development, the specifications herein are subject to change without notice.
• Specifications and battery cartridge may differ from country to country.
• Weight, with battery cartridge, according to EPTA-Procedure 01/2003
END004-6
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
・ Read instruction manual.
・ Only for EU countries
Do not dispose of electric equipment or
battery pack together with household
waste material!
In observance of the European
Directives, on Waste Electric and
Electronic Equipment and Batteries and
Accumulators and Waste Batteries and
Accumulators and their implementation
in accordance with national laws,
electric equipment and batteries and
battery pack(s) that have reached the
end of their life must be collected
separately and returned to an
environmentally compatible recycling
facility.
ENE033-1
Intended use
The tool is intended for screw driving in wood, metal and
plastic.
ENG905-1
Noise
The typical A-weighted noise level determined according
to EN60745:
Model DTD134
Sound pressure level (L
pA
) : 92 dB (A)
Sound power level (L
WA
) : 103 dB (A)
Uncertainty (K) : 3 dB (A)
Model DTD146
Sound pressure level (L
pA
) : 93 dB (A)
Sound power level (L
WA
) : 104 dB (A)
Uncertainty (K) : 3 dB (A)
Wear ear protection
ENG900-1
Vibration
The vibration total value (tri-axial vector sum)
determined according to EN60745:
Model DTD134
Work mode : impact tightening of fasteners of the
maximum capacity of the tool
Vibration emission (a
h
) : 12.0 m/s
2
Uncertainty (K) : 1.5 m/s
2
Model DTD146
Work mode : impact tightening of fasteners of the
maximum capacity of the tool
Vibration emission (a
h
) : 15.5 m/s
2
Uncertainty (K) : 2.0 m/s
2
ENG901-1
•
The declared vibration emission value has been
measured in accordance with the standard test
method and may be used for comparing one tool
with another.
• The declared vibration emission value may also be
used in a preliminary assessment of exposure.
WARNING:
•
The vibration emission during actual use of the power
tool can differ from the declared emission value
depending on the ways in which the tool is used.
Cd
Ni-MH
Li-ion