2
ENGLISH (Original instructions)
SPECIFICATIONS
Model PC5000C PC5001C
Wheel diameter 125 mm
Hole diameter 22.23 mm
Spindle thread M14
Rated speed (n)/No load speed (n
0
) 10,000 min
-1
Overall length 437 mm 479 mm
Net weight 4.0 kg 5.1 kg
Safety class /II
• Due to our continuing program of research and development, the specifications herein are subject to change without notice.
• Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
END202-6
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
읭 Read instruction manual.
읭 DOUBLE INSULATION
읭 Wear safety glasses.
읭 Only for EU countries
Do not dispose of electric equipment
together with household waste material!
In observance of European Directive
2002/96/EC on waste electric and
electronic equipment and its
implementation in accordance with
national law, electric equipment that
have reached the end of their life must
be collected separately and returned to
an environmentally compatible
recycling facility.
ENE002-1
Intended use
The tool is intended for planing concrete surfaces.
ENF002-2
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
ENG905-1
Noise
The typical A-weighted noise level determined
according to EN60745:
Model PC5000C
Sound pressure level (L
pA
) : 91 dB(A)
Sound power level (L
WA
) : 102 dB(A)
Uncertainty (K) : 3 dB(A)
Model PC5001C
Sound pressure level (L
pA
) : 89 dB(A)
Sound power level (L
WA
) : 100 dB(A)
Uncertainty (K) : 3 dB(A)
Wear ear protection
ENG900-1
Vibration
The vibration total value (tri-axial vector sum)
determined according to EN60745:
Model PC5000C
Work mode : planing concrete
Vibration emission (a
h
) : 12.0 m/s
2
Uncertainty (K) : 1.5 m/s
2
Model PC5001C
Work mode : planing concrete
Vibration emission (a
h
) : 12.5 m/s
2
Uncertainty (K) : 2.5 m/s
2
ENG902-1
•
The declared vibration emission value has been
measured in accordance with the standard test
method and may be used for comparing one tool
with another.
• The declared vibration emission value may also be
used in a preliminary assessment of exposure.
• The declared vibration emission value is used for
main applications of the power tool. However if the
power tool is used for other applications, the
vibration emission value may be different.