Commissioning and operation
20
Commissioning
Before daily starting the engine, check fuel level, coolant level and engine oil level and
replenish, if necessary.
Caution:
Use only approved fuels, lubricants etc. (see brochure “Fuels, lubricants etc.”).
Otherwise the manufacturer’s warranty will become null and void.
Checking oil level
Check engine oil level only approx.
20 minutes after the unit has been
switched off.
D Pull out dipstick (arrow)
D wipe it with a clean, lintfree cloth
D and push it in again up to the stop
D Pull out dipstick again
The oil level should be between the two
notches in the dipstick and must never fall
below the lower notch. Top up oil as nec-
essary.
Caution:
Do not add so much engine oil
that the oil level rises above the
max. marking on the dipstick.
Overfilling will result in damage to
the engine.
Ensure outmost cleanliness when han-
dling fuels, lubricants and coolants.
Oil
?
MIN