Cabin heater
64
Basic setup
The control stand and the ship’s quarters can be heated with a part of the heat generated by the engine in
the coolant. For this purpose part of the coolant is bypassed through a heat exchanger. The heat generated
there can be used to heat the cabins.
6
5
1
2
3
4
À Feed line of engine coolant to heat exchanger
Á Return line from cabin heater
 Feed line to cabin heater
à Circulation pump
Ä Heat exchanger
Å Return line of engine coolant
Utilisable coolant heat
Engine model Utilisable coolant heat
kW
V12−1800 18
V8−1200 12