234 Part Number 80-1505-3 6/11
FAN CYCLE CONTROL
HIGH PRESSURE CUTOUT (HPCO) CONTROL
LOW PRESSURE CUTOUT (LPCO) CONTROL
Specifications
Cut-In (Close) Cut-Out (Open)
First Condenser Fan
250 psig ±5 200 psig ±5
Second Condenser Fan
275 psig ±5 225 psig ±5
Specifications
Cut-Out Cut-In
450 psig ±10
(3103 kPa ±69)
31 bar ±.69
Automatic Reset
(Must be below 300 psig
{2068 kPa 20.68 bar} to reset.)
Specifications
Cut-Out Cut-In
Original 7 psig ±3 22 psig ±3
Current Production &
Replacement Part
12 psig ±3 35 psig ±3