Part Number 000014141 Rev 07 2/20 23
Section 2 Installation
Water Supply and Drain Connections
,
Caution
Do not apply heat to water inlet valve or
water drain fittings. Heating will damage
the nonmetallic connector. Do not over
tighten fittings. Two turns after hand tight
is the maximum.
Item Description
1 Electrical Entrance
2
Vent Tube - Minimum Height
18" (46 cm)
3 Potable Water Inlet - 3/8" FPT
4 Potable Water Drain - 1/2" FPT
5
Condenser Water Outlet - 1/2" FPT
Water-cooled Models Only
Install Separate Drain When Used
6
Condenser Water Inlet
See “Condenser Water Inlet” on
page 22 for fitting sizes
7 Base Drain - 1/2" CPVC Socket
8
Bin Drain - See “Bin Drain” on page
22 for fitting sizes
9 Floor Drain - Open and Trapped
10
Do Not Trap Drain Line - Leave Air
Gap Between Drain Line and Floor
Drain
AIR GAP
A greater than 1-inch air gap is built into
the ice machine for back-flow prevention.
This air gap exceeds NSF 12 requirements
for back-flow prevention.
This air gap is greater than 1"
INSTALLATION NOTE (SWITZERLAND)
The connection to the drinking water
network must be made with a certified
backflow preventer type EA (EN13959)
and with a certified connection hose
(EN13618 or EN61770) on site.
1
2
3
4
5 6
7
8
9
10

Other manuals for Manitowoc CVDF1400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc CVDF1400 and is the answer not in the manual?

Manitowoc CVDF1400 Specifications

General IconGeneral
BrandManitowoc
ModelCVDF1400
CategoryIce Maker
LanguageEnglish

Related product manuals