24 Part Number: 000015431 Rev01 5/19
LuminIce® II
The LuminIce® growth inhibitor recirculates the air in the
ice machine foodzone over a UV bulb. This process will
inhibit the growth of common micro-organisms on all
exposed foodzone surfaces.
LuminIce® bulbs require replacement on a yearly basis.
The control board can be set to automatically display a
reminder after 12 months.
NOTE: LuminIce® and LuminIce® II bulbs are not
interchangeable; verify your model before ordering a
replacement bulb. LuminIce® bulbs have a white base and
LuminIce® II bulbs have a blue base.
Cleanup Procedure for Accidental Bulb Breakage
The cleanup procedure is identical to the procedure used
to clean up compact fluorescent (CFL) or fluorescent tube
lights. These lights contain a small amount of mercury
sealed within a glass tube. Breaking these types of lights
will release mercury and mercury vapor. The broken bulb
can continue to release mercury vapor until it is cleaned up
and removed.
The latest EPA procedures can be viewed on their website
at www.epa.gov/cfl/cflcleanup.html.

Table of Contents

Other manuals for Manitowoc IDF1800C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc IDF1800C and is the answer not in the manual?

Manitowoc IDF1800C Specifications

General IconGeneral
BrandManitowoc
ModelIDF1800C
CategoryIce Maker
LanguageEnglish

Related product manuals