EasyManuals Logo
Home>Manitowoc>Ice Maker>IDF1800C

Manitowoc IDF1800C User Manual

Manitowoc IDF1800C
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
42 Part Number 000014141 Rev 07 2/20
Operation Section 3
Reverse Osmosis or Deionized Water
Usage
When using water with low total dissolved
solid content (low TDS) the water level
probe sensitivity can be increased by
moving the jumper over one pin.
The Electronic Control Board diagram
shows the default position of the jumper
covering the left and center pins. Moving
the jumper to the center and right pins
and enabling R.O. menu “Use less water
with reverse osmosis” (Settings/Energy/
Water Usage/Use Less Water With Reverse
Osmosis) will increase the sensitivity of the
water level probe.
Move jumper from left & center
pins to center and right pins

Other manuals for Manitowoc IDF1800C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc IDF1800C and is the answer not in the manual?

Manitowoc IDF1800C Specifications

General IconGeneral
BrandManitowoc
ModelIDF1800C
CategoryIce Maker
LanguageEnglish

Related product manuals