174 Part Number: 000015431 Rev01 5/19
Important
Dry nitrogen is recommended for this procedure. This
will prevent refrigerant release.
9. Follow the normal evacuation procedure, except
replace the evacuation step with the following:
A. Pull vacuum to 1000 microns. Break the vacuum
with dry nitrogen and sweep the system.
Pressurize to a minimum of 5 psig (35 kPa,
.35 bar).
B. Change the vacuum pump oil.
C. Pull vacuum to 500 microns. Break the vacuum
with dry nitrogen and sweep the system.
Pressurize to a minimum of 5 psig (35 kPa,
.35 bar).
D. Change the vacuum pump oil.
E. Pull vacuum to 500 microns. Run the vacuum
pump for 1 hour.
NOTE: You may perform a standing vacuum test to make a
preliminary leak check. You should use an electronic leak
detector after system charging to be sure there are no
leaks.
10. Charge the system with the proper refrigerant to the
nameplate charge.
11. Operate the ice machine for one hour. Then, check
the pressure drop across the suction line filter-drier.
A. If the pressure drop is less than 1 psig (7 kPa,
0.07 bar), the filter-drier should be adequate for
complete cleanup.
B. If the pressure drop exceeds 1 psig (7 kPa,
0.07 bar), change the suction line filter-drier and
the liquid line drier. Repeat until the pressure
drop is acceptable.
12. Operate the ice machine for 48-72 hours. Then
remove the suction line drier and change the liquid
line drier.
13. Follow normal evacuation procedures.

Table of Contents

Other manuals for Manitowoc Indigo NXT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Indigo NXT Series and is the answer not in the manual?

Manitowoc Indigo NXT Series Specifications

General IconGeneral
ModelIndigo NXT Series
Ice ProductionVaries by model
Ice StorageVaries by model
Energy EfficiencyEnergy Star certified models available
RefrigerantR290 (varies by model)
Cooling SystemAir-cooled or water-cooled (varies by model)
Condenser TypeAir-cooled, Water-cooled, or Remote
Touch DisplayYes, with intuitive interface
ControlCleaning Alerts
FeaturesSelf-cleaning, remote monitoring, energy-saving modes
Power SupplyVaries by model (typically 115V or 208-230V)
Dimensions (H x W x D)Varies by model
WeightVaries by model

Related product manuals