Part Number STH042 7/15 119
REPLACING PRESSURE CONTROLS WITHOUT
REMOVING REFRIGERANT CHARGE
This procedure reduces repair time and cost. Use it when
any of the following components require replacement,
and the refrigeration system is operational and leak-free.
Fan cycle control
High pressure cut-out control
High side access valve
Low side access valve
Important
This is a required in-warranty repair procedure.
1. Disconnect power to the ice machine.
2. Follow all manufacturers’ instructions supplied
with the pinch-off tool. Position the pinch-off tool
around the tubing as far from the pressure control as
feasible. (See the figure on next page.) Clamp down
on the tubing until the pinch-off is complete.
Warning
Do not unsolder a defective component. Cut it out
of the system. Do not remove the pinch-off tool until
the new component is securely in place.
3. Cut the tubing of the defective component with a
small tubing cutter.
4. Solder the replacement component in place. Allow
the solder joint to cool.
5. Remove the pinch-off tool.
6. Re-round the tubing. Position the flattened tubing
in the proper hole in the pinch off tool. Tighten the
wing nuts until the block is tight and the tubing is
rounded.
NOTE: The pressure controls will operate normally once
the tubing is re-rounded. Tubing may not re-round 100%.

Table of Contents

Other manuals for Manitowoc NEO UD0140A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc NEO UD0140A and is the answer not in the manual?

Manitowoc NEO UD0140A Specifications

General IconGeneral
BrandManitowoc
ModelNEO UD0140A
CategoryIce Maker
LanguageEnglish

Related product manuals