Section 2 Installation Instructions
Part Number 040002909 11/13 11
Water Supply and Drain Line Sizing/Connections
ICE THICKNESS ADJUSTMENT
The ice thickness can be adjusted to three levels.
1. Pull forward on the bottom of the bracket until clear
of the tab.
2. Slide the bracket over the desired tab and release.
• The center position is the normal factory setting.
• To increase bridge thickness, raise the water level.
• To decrease bridge thickness, lower the water level.
WATER/DRAIN CONNECTIONS
A. Potable Water Inlet
B. Drain
C. Condenser Water Inlet - (Water-cooled Only)
D. Condenser Water Outlet - (Water-cooled Only)
Location Water
Temperature
Water
Pressure
Ice Machine
Fitting
Tubing Size Up to Ice
Machine Fitting
Ice Making
Water Inlet
40°F (4°C) Min.
90°F (32°C) Max.
20 psi (137.9 kPA) Min.
80 psi (551.5 kPA) Max.
3/8" Female Pipe
Thread
3/8" (9.5 mm) minimum
inside diameter
Condenser Water
Inlet
40°F (4°C) Min.
90°F (32°C) Max.
20 psi (137.9 kPA) Min.
150 psi (1034.2 kPA) Max.
3/8" Female Pipe
Thread
U310 Only
1/2" Female Pipe
Thread
3/8" (9.5 mm) minimum
inside diameter
U310 Only
1/2" (12.7 mm)
minimum inside diameter
Condenser Water
Drain
--- --- 1/2" Female Pipe
Thread
1/2" (12.7 mm) minimum
inside diameter
Bin Drain
--- --- 1/2" Female Pipe
Thread
1/2" (12.7 mm) minimum
inside diameter
Thinner
Bridge
Factory
Default
Setting
Thicker
Bridge