Part Number STH042 7/15 33
Caution
Do not mix Ice Machine Cleaner and Sanitizer
solutions together. It is a violation of Federal law to
use these solutions in a manner inconsistent with
their labeling.
Step 3 To start a cleaning cycle, press the Clean
button. Water will flow through the water dump valve
and down the drain. Wait until the water trough refills,
then add the proper amount of ice machine cleaner to
the water trough.
Model Amount of Cleaner
U0140 2 ounces (60 ml)
U0190 5 ounces (150 ml)
U0240 5 ounces (150 ml)
U0310 5 ounces (150 ml)
Wait until the clean cycle is complete (approximately 22
minutes) then press the On/Off button and disconnect
power and water supplies to the ice machine.
Step 4 Remove parts for cleaning.
Refer to the proper parts removal for your machine.
Continue with step 5 when the parts have been removed.