Page #184 background imageLoading...
Page #184 background image
184 Part Number 80-01111-9 7/10
RECOVERY AND RECHARGING PROCEDURES
Q130/Q170/Q210/Q270
Do not purge refrigerant to the atmosphere. Capture
refrigerant using recovery equipment. Follow the
manufacturers recommendations.
CONNECTIONS
1. Suction side of the compressor through the
suction service valve.
2. Discharge side of the compressor through the
discharge service valve.
Important
Manitowoc Ice assumes no responsibility for the
use of contaminated refrige rant. Damag e
resulting from the use of contaminated refrigerant
is the sole responsibility of the servicing company.
Important
Replace the liq uid line drie r before e vacuating
and recharging. Use only a Man itowoc (O.E.M.)
liquid line filter dri er to pre vent void ing the
warranty.